FabDigitFabDigit

Copper Alloy C19020-H02 vs C19020-HR06

Copper Alloy · C19020 temper comparison

C19020-H02 and C19020-HR06 are two conditions of the same copper alloy grade, C19020: H02 (half hard) versus HR06 (extra hard, cold rolled and stress relieved). The chemistry is identical, so every difference below comes from the condition. C19020-HR06 is the stronger of the two: yield strength 545 MPa (79 ksi) against 380 MPa (55.1 ksi) for C19020-H02, about 43% more; tensile strength follows at 570 MPa (82.7 ksi) vs 425 MPa (61.6 ksi). In exchange, C19020-H02 is the more ductile: elongation 12% versus 4% for C19020-HR06, and C19020-HR06 is harder (166 HB vs 123 HB). C19020-HR06 runs hotter in service (165°C vs 120°C continuous).

C19020-H02Choose it when the part is bent, formed or impact-loaded.

C19020-HR06Choose it when strength drives the design, or when the part sees heat.

C19020-H02 vs C19020-HR06: properties

C19020-H02C19020-HR06

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

425 MPa61.6 ksi
570 MPa82.7 ksi

Yield Strength (0.2% offset)

380 MPa55.1 ksi
545 MPa79 ksi

Elongation at Break

12%
4%

Shear Strength

265 MPa38.4 ksi
355 MPa51.5 ksi

Fatigue Strength (Endurance Limit)

185 MPa26.8 ksi
245 MPa35.5 ksi

Hardness, Brinell

123 HB
166 HB

Hardness, Rockwell B

72 HRB
87 HRB

Hardness, Vickers

130 HV
175 HV

Same in both: Elastic (Young's) Modulus 125 GPa18.1 Msi · Shear Modulus 47 GPa6.8 Msi · Bulk Modulus 138 GPa20 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 8.9 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,065°C1,949 °F · Liquidus Temperature 1,085°C1,985 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

165 W/m·K95.3 BTU/hr·ft·°F
180 W/m·K104 BTU/hr·ft·°F

Max Service Temperature (continuous)

120°C248 °F
165°C329 °F

Same in both: Specific Heat Capacity 385 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 17.6 µm/m·K9.8 µin/in·°F · Latent Heat of Fusion 205 J/g88.1 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

41 % IACS
45 % IACS

Electrical Resistivity

4.2×10⁻⁸ Ω·m1.65 µΩ·in
3.83×10⁻⁸ Ω·m1.51 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.2 V · Corrosion Resistance 62 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

30 / 100
32 / 100

Formability (cold)

70 / 100
45 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 20% · Weldability 45 / 100 · Brazeability / Solderability 90 / 100 · Polishability 75 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 57 MJ/kg24,506 BTU/lb · Embodied Carbon (primary production) 3.8 kg CO₂/kg · Embodied Water 300 L/kg35.9 gal/lb · Typical Recycled Content 35%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC19020

C19020-H02 vs C19020-HR06 — frequently asked

Is C19020-HR06 stronger than C19020-H02?

Yes. C19020-HR06 has a typical yield strength of 545 MPa (79 ksi) against 380 MPa (55.1 ksi) for C19020-H02 — about 43% more. Tensile strength is 570 MPa (82.7 ksi) vs 425 MPa (61.6 ksi).

Which condition does FabDigit quote by default, H02 or HR06?

HR04 is the default C19020 condition in the FabDigit quote flow (neither H02 nor HR06). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C19020-H02 over C19020-HR06?

Pick C19020-H02 when the part is bent, formed or impact-loaded. Pick C19020-HR06 when strength drives the design, or when the part sees heat.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C19020-H02 and C19020-HR06 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.