FabDigitFabDigit

Copper Alloy C18700-H02 vs C18700-M20

Copper Alloy · C18700 temper comparison

C18700-H02 and C18700-M20 are two conditions of the same copper alloy grade, C18700: H02 (half hard) versus M20 (as hot rolled). The chemistry is identical, so every difference below comes from the condition. C18700-H02 is the stronger of the two: yield strength 220 MPa (31.9 ksi) against 85 MPa (12.3 ksi) for C18700-M20, about 159% more; tensile strength follows at 276 MPa (40 ksi) vs 230 MPa (33.4 ksi). In exchange, C18700-M20 is the more ductile: elongation 40% versus 25% for C18700-H02, and C18700-H02 is harder (78 HB vs 48 HB).

C18700-H02Choose it when strength drives the design.

C18700-M20Choose it when the part is bent, formed or impact-loaded.

C18700-H02 vs C18700-M20: properties

C18700-H02C18700-M20

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

117 GPa17 Msi
115 GPa16.7 Msi

Tensile Strength (Ultimate)

276 MPa40 ksi
230 MPa33.4 ksi

Yield Strength (0.2% offset)

220 MPa31.9 ksi
85 MPa12.3 ksi

Elongation at Break

25%
40%

Reduction in Area

62%
72%

Shear Strength

185 MPa26.8 ksi
150 MPa21.8 ksi

Fatigue Strength (Endurance Limit)

100 MPa14.5 ksi
75 MPa10.9 ksi

Hardness, Brinell

78 HB
48 HB

Hardness, Rockwell B

38 HRB
47 HRB

Hardness, Vickers

82 HV
52 HV

Same in both: Shear Modulus 44 GPa6.4 Msi · Bulk Modulus 140 GPa20.3 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 8.94 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,075°C1,967 °F · Liquidus Temperature 1,083°C1,981 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

190°C374 °F
200°C392 °F

Same in both: Thermal Conductivity 372 W/m·K215 BTU/hr·ft·°F · Specific Heat Capacity 385 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 17.7 µm/m·K9.8 µin/in·°F · Latent Heat of Fusion 205 J/g88.1 BTU/lb · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

95 % IACS
96 % IACS

Electrical Resistivity

1.82×10⁻⁸ Ω·m0.715 µΩ·in
1.8×10⁻⁸ Ω·m0.707 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.25 V · Corrosion Resistance 64 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

87 / 100
80 / 100

Machinability Rating (AISI 1212 = 100 %)

78%
72%

Formability (cold)

48 / 100
60 / 100

Same in both: Weldability 15 / 100 · Brazeability / Solderability 55 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 57 MJ/kg24,506 BTU/lb · Embodied Carbon (primary production) 3.6 kg CO₂/kg · Embodied Water 250 L/kg30 gal/lb · Typical Recycled Content 40%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC18700

C18700-H02 vs C18700-M20 — frequently asked

Is C18700-H02 stronger than C18700-M20?

Yes. C18700-H02 has a typical yield strength of 220 MPa (31.9 ksi) against 85 MPa (12.3 ksi) for C18700-M20 — about 159% more. Tensile strength is 276 MPa (40 ksi) vs 230 MPa (33.4 ksi).

Which condition does FabDigit quote by default, H02 or M20?

H04 is the default C18700 condition in the FabDigit quote flow (neither H02 nor M20). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, C18700-H02 or C18700-M20?

C18700-H02. Its machinability rates excellent (87/100) against very good (80/100) for C18700-M20.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C18700-H02 and C18700-M20 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.