C18400-TB00 and C18400-TD02 are two conditions of the same copper alloy grade, C18400: TB00 (solution heat treated) versus TD02 (solution heat treated and cold worked, half hard). The chemistry is identical, so every difference below comes from the condition. C18400-TD02 is the stronger of the two: yield strength 330 MPa (47.9 ksi) against 95 MPa (13.8 ksi) for C18400-TB00, about 3.5 times as much; tensile strength follows at 380 MPa (55.1 ksi) vs 240 MPa (34.8 ksi). In exchange, C18400-TB00 is the more ductile: elongation 40% versus 14% for C18400-TD02, and C18400-TD02 is harder (110 HB vs 60 HB). C18400-TD02 runs hotter in service (250°C vs 150°C continuous) and C18400-TD02 conducts heat better (300 W/m·K vs 190 W/m·K). On the shop floor, C18400-TD02 machines more easily (45 vs 35 out of 100).

C18400-TB00Choose it when the part is bent, formed or impact-loaded.

C18400-TD02Choose it when strength drives the design, or when the part sees heat.

C18400-TB00 vs C18400-TD02: properties

C18400-TB00C18400-TD02

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

240 MPa34.8 ksi
380 MPa55.1 ksi

Yield Strength (0.2% offset)

95 MPa13.8 ksi
330 MPa47.9 ksi

Elongation at Break

40%
14%

Reduction in Area

70%
55%

Shear Strength

165 MPa23.9 ksi
250 MPa36.3 ksi

Fatigue Strength (Endurance Limit)

95 MPa13.8 ksi
150 MPa21.8 ksi

Hardness, Brinell

60 HB
110 HB

Hardness, Rockwell B

30 HRB
65 HRB

Same in both: Elastic (Young's) Modulus 115 GPa16.7 Msi · Shear Modulus 44 GPa6.4 Msi · Bulk Modulus 138 GPa20 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 8.89 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,070°C1,958 °F · Liquidus Temperature 1,080°C1,976 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

190 W/m·K110 BTU/hr·ft·°F
300 W/m·K173 BTU/hr·ft·°F

Max Service Temperature (continuous)

150°C302 °F
250°C482 °F

Same in both: Specific Heat Capacity 385 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 17 µm/m·K9.4 µin/in·°F · Latent Heat of Fusion 205 J/g88.1 BTU/lb · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

42 % IACS
75 % IACS

Electrical Resistivity

4.1×10⁻⁸ Ω·m1.61 µΩ·in
2.3×10⁻⁸ Ω·m0.906 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.28 V · Corrosion Resistance 68 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

35 / 100
45 / 100

Formability (cold)

80 / 100
50 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 60% · Weldability 45 / 100 · Castability 55 / 100 · Brazeability / Solderability 70 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 57 MJ/kg24,506 BTU/lb · Embodied Carbon (primary production) 3.8 kg CO₂/kg · Embodied Water 250 L/kg30 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC18400

C18400-TB00 vs C18400-TD02 — frequently asked

Is C18400-TD02 stronger than C18400-TB00?

Yes. C18400-TD02 has a typical yield strength of 330 MPa (47.9 ksi) against 95 MPa (13.8 ksi) for C18400-TB00 — about 3.5 times as much. Tensile strength is 380 MPa (55.1 ksi) vs 240 MPa (34.8 ksi).

Which condition does FabDigit quote by default, TB00 or TD02?

TF00 is the default C18400 condition in the FabDigit quote flow (neither TB00 nor TD02). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, C18400-TB00 or C18400-TD02?

C18400-TD02, by a small margin. Both rate fair for machinability — 45/100 against 35/100 for C18400-TB00.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C18400-TB00 and C18400-TD02 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.