C18200-TF00 and C18200-TH02 are two conditions of the same copper alloy grade, C18200: TF00 (solution heat treated and precipitation hardened) versus TH02 (TD02 and precipitation hardened). The chemistry is identical, so every difference below comes from the condition. C18200-TH02 is the stronger of the two: yield strength 427 MPa (61.9 ksi) against 372 MPa (54 ksi) for C18200-TF00, about 15% more; tensile strength follows at 496 MPa (71.9 ksi) vs 448 MPa (65 ksi). In exchange, C18200-TF00 is the more ductile: elongation 22% versus 18% for C18200-TH02, and C18200-TH02 is harder (140 HB vs 120 HB).

C18200-TF00Choose it when the part is bent, formed or impact-loaded.

C18200-TH02Choose it when strength drives the design.

C18200-TF00 vs C18200-TH02: properties

C18200-TF00C18200-TH02

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

448 MPa65 ksi
496 MPa71.9 ksi

Yield Strength (0.2% offset)

372 MPa54 ksi
427 MPa61.9 ksi

Elongation at Break

22%
18%

Shear Strength

285 MPa41.3 ksi
310 MPa45 ksi

Fatigue Strength (Endurance Limit)

160 MPa23.2 ksi
170 MPa24.7 ksi

Hardness, Brinell

120 HB
140 HB

Hardness, Rockwell B

68 HRB
75 HRB

Hardness, Vickers

128 HV
145 HV

Same in both: Elastic (Young's) Modulus 117 GPa17 Msi · Shear Modulus 44 GPa6.4 Msi · Bulk Modulus 133 GPa19.3 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Same in both: Density 8.89 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,070°C1,958 °F · Liquidus Temperature 1,080°C1,976 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

324 W/m·K187 BTU/hr·ft·°F
320 W/m·K185 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 385 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 17.6 µm/m·K9.8 µin/in·°F · Latent Heat of Fusion 205 J/g88.1 BTU/lb · Max Service Temperature (continuous) 400°C752 °F · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 82 % IACS · Electrical Resistivity 2.1×10⁻⁸ Ω·m0.827 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.3 V · Corrosion Resistance 62 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Formability (cold)

45 / 100
35 / 100

Same in both: Machinability 40 / 100 · Machinability Rating (AISI 1212 = 100 %) 60% · Weldability 30 / 100 · Brazeability / Solderability 75 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 57 MJ/kg24,506 BTU/lb · Embodied Carbon (primary production) 3.5 kg CO₂/kg · Embodied Water 350 L/kg41.9 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC18200

C18200-TF00 vs C18200-TH02 — frequently asked

Is C18200-TH02 stronger than C18200-TF00?

Yes. C18200-TH02 has a typical yield strength of 427 MPa (61.9 ksi) against 372 MPa (54 ksi) for C18200-TF00 — about 15% more. Tensile strength is 496 MPa (71.9 ksi) vs 448 MPa (65 ksi).

Which condition does FabDigit quote by default, TF00 or TH02?

H is the default C18200 condition in the FabDigit quote flow (neither TF00 nor TH02). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C18200-TF00 over C18200-TH02?

Pick C18200-TF00 when the part is bent, formed or impact-loaded. Pick C18200-TH02 when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C18200-TF00 and C18200-TH02 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.