Copper Alloy C17500-TD04 vs C17500-TF00
Copper Alloy · C17500 temper comparison
C17500-TD04 and C17500-TF00 are two conditions of the same copper alloy grade, C17500: TD04 (solution heat treated and cold worked, full hard) versus TF00 (solution heat treated and precipitation hardened). The chemistry is identical, so every difference below comes from the condition. C17500-TF00 is the stronger of the two: yield strength 620 MPa (89.9 ksi) against 500 MPa (72.5 ksi) for C17500-TD04, about 24% more; tensile strength follows at 760 MPa (110 ksi) vs 550 MPa (79.8 ksi). C17500-TF00 is the more ductile: elongation 15% versus 8% for C17500-TD04, and C17500-TF00 is harder (220 HB vs 160 HB). C17500-TF00 runs hotter in service (350°C vs 200°C continuous) and C17500-TF00 conducts heat better (215 W/m·K vs 110 W/m·K).
C17500-TF00Choose it when strength drives the design, or when the part is bent, formed or impact-loaded.
C17500-TD04 vs C17500-TF00: propertiesHow to read these bars
- One bar per material. A full bar is the highest value among all copper alloy grades in the FabDigit library; each bar is drawn as a share of that.
- The better value (by the usual engineering direction) is in bold. Rows with no direction — density, thermal conductivity — have no bold.
- Values are typical room-temperature figures for the condition named on each card.
- Confirm against the certified mill or resin datasheet before design release.
How to read these bars
- One bar per material. A full bar is the highest value among all copper alloy grades in the FabDigit library; each bar is drawn as a share of that.
- The better value (by the usual engineering direction) is in bold. Rows with no direction — density, thermal conductivity — have no bold.
- Values are typical room-temperature figures for the condition named on each card.
- Confirm against the certified mill or resin datasheet before design release.
Mechanical
Strength, stiffness, ductility and hardness at room temperature.
Tensile Strength (Ultimate)
Yield Strength (0.2% offset)
Elongation at Break
Fatigue Strength (Endurance Limit)
Hardness, Brinell
Hardness, Rockwell B
Same in both: Elastic (Young's) Modulus 138 GPa20 Msi · Shear Modulus 53 GPa7.7 Msi · Bulk Modulus 115 GPa16.7 Msi · Poisson's Ratio 0.3 · Reduction in Area 35% · Shear Strength 430 MPa62.4 ksi · Hardness, Rockwell C 23 HRC · Hardness, Vickers 230 HV
Physical
Density and transition temperatures.
Same in both: Density 8.75 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,030°C1,886 °F · Liquidus Temperature 1,070°C1,958 °F
Thermal
How each material carries heat and how hot it can run.
Thermal Conductivity
Max Service Temperature (continuous)
Same in both: Specific Heat Capacity 419 J/kg·K0.1 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 17.6 µm/m·K9.8 µin/in·°F · Latent Heat of Fusion 205 J/g88.1 BTU/lb · Min Service Temperature -200°C-328 °F
Electrical
Conductivity and insulation.
Electrical Conductivity
Electrical Resistivity
Chemical & Environmental
Corrosion and environmental resistance (0–100 scores).
Same in both: Galvanic Potential (seawater, vs SCE) -0.22 V · Corrosion Resistance 65 / 100
Manufacturability
FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.
Machinability
Formability (cold)
Same in both: Machinability Rating (AISI 1212 = 100 %) 20% · Weldability 60 / 100 · Castability 55 / 100 · Brazeability / Solderability 65 / 100 · Polishability 80 / 100
Sustainability
Primary-production footprint per kilogram.
Same in both: Embodied Energy (primary production) 95 MJ/kg40,843 BTU/lb · Embodied Carbon (primary production) 6.5 kg CO₂/kg · Embodied Water 300 L/kg35.9 gal/lb · Typical Recycled Content 30%
Strength versus weight
Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.
C17500-TD04 vs C17500-TF00 — frequently asked
Is C17500-TF00 stronger than C17500-TD04?
Yes. C17500-TF00 has a typical yield strength of 620 MPa (89.9 ksi) against 500 MPa (72.5 ksi) for C17500-TD04 — about 24% more. Tensile strength is 760 MPa (110 ksi) vs 550 MPa (79.8 ksi).
Which condition does FabDigit quote by default, TD04 or TF00?
TF00 is the default C17500 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.
Which is easier to machine, C17500-TD04 or C17500-TF00?
C17500-TD04, by a small margin. Both rate fair for machinability — 45/100 against 40/100 for C17500-TF00.
Ready to make it?
Upload a CAD file and FabDigit prices the part in C17500-TD04 and C17500-TF00 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.
Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.
