FabDigitFabDigit

Copper Alloy C17200-TD04 vs C17200-TH01

Copper Alloy · C17200 temper comparison

C17200-TD04 and C17200-TH01 are two conditions of the same copper alloy grade, C17200: TD04 (solution heat treated and cold worked, full hard) versus TH01 (TD01 and precipitation hardened). The chemistry is identical, so every difference below comes from the condition. C17200-TH01 is the stronger of the two: yield strength 1,140 MPa (165 ksi) against 690 MPa (100 ksi) for C17200-TD04, about 65% more; tensile strength follows at 1,275 MPa (185 ksi) vs 760 MPa (110 ksi). In exchange, C17200-TD04 is the more ductile: elongation 5% versus 4% for C17200-TH01, and C17200-TH01 is harder (375 HB vs 225 HB). C17200-TH01 runs hotter in service (200°C vs 150°C continuous) and C17200-TH01 conducts heat better (125 W/m·K vs 105 W/m·K). On the shop floor, C17200-TD04 welds better (fair vs poor).

C17200-TD04Choose it when the part is bent, formed or impact-loaded, or when it will be welded.

C17200-TH01Choose it when strength drives the design, or when the part sees heat.

C17200-TD04 vs C17200-TH01: properties

C17200-TD04C17200-TH01

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

128 GPa18.6 Msi
131 GPa19 Msi

Tensile Strength (Ultimate)

760 MPa110 ksi
1,275 MPa185 ksi

Yield Strength (0.2% offset)

690 MPa100 ksi
1,140 MPa165 ksi

Elongation at Break

5%
4%

Reduction in Area

25%
8%

Shear Strength

480 MPa69.6 ksi
750 MPa109 ksi

Fatigue Strength (Endurance Limit)

240 MPa34.8 ksi
260 MPa37.7 ksi

Charpy V-Notch Impact (RT)

25 J18.4 ft·lbf
12 J8.9 ft·lbf

Hardness, Brinell

225 HB
375 HB

Hardness, Rockwell B

99 HRB
62 HRB

Same in both: Shear Modulus 49 GPa7.1 Msi · Bulk Modulus 107 GPa15.5 Msi · Poisson's Ratio 0.3

Physical

Density and transition temperatures.

Same in both: Density 8.26 g/cm³0.3 lb/in³ · Melting Point (Solidus) 865°C1,589 °F · Liquidus Temperature 980°C1,796 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

105 W/m·K60.7 BTU/hr·ft·°F
125 W/m·K72.2 BTU/hr·ft·°F

Max Service Temperature (continuous)

150°C302 °F
200°C392 °F

Same in both: Specific Heat Capacity 420 J/kg·K0.1 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 17 µm/m·K9.4 µin/in·°F · Latent Heat of Fusion 205 J/g88.1 BTU/lb · Min Service Temperature -250°C-418 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

17 % IACS
22 % IACS

Electrical Resistivity

1.01×10⁻⁷ Ω·m3.98 µΩ·in
7.8×10⁻⁸ Ω·m3.07 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.25 V · Corrosion Resistance 65 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

45 / 100
50 / 100

Machinability Rating (AISI 1212 = 100 %)

25%
30%

Weldability

45 / 100
30 / 100

Formability (cold)

30 / 100
15 / 100

Same in both: Castability 50 / 100 · Brazeability / Solderability 80 / 100 · Polishability 85 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 95 MJ/kg40,843 BTU/lb · Embodied Carbon (primary production) 6.5 kg CO₂/kg · Embodied Water 280 L/kg33.6 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC17200

C17200-TD04 vs C17200-TH01 — frequently asked

Is C17200-TH01 stronger than C17200-TD04?

Yes. C17200-TH01 has a typical yield strength of 1,140 MPa (165 ksi) against 690 MPa (100 ksi) for C17200-TD04 — about 65% more. Tensile strength is 1,275 MPa (185 ksi) vs 760 MPa (110 ksi).

Which condition does FabDigit quote by default, TD04 or TH01?

A is the default C17200 condition in the FabDigit quote flow (neither TD04 nor TH01). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, C17200-TD04 or C17200-TH01?

C17200-TH01, by a small margin. Both rate fair for machinability — 50/100 against 45/100 for C17200-TD04; for welding the order is C17200-TD04 first (fair, 45/100) then C17200-TH01 (poor, 30/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in C17200-TD04 and C17200-TH01 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.