C17200-TD02 and C17200-TF00 are two conditions of the same copper alloy grade, C17200: TD02 (solution heat treated and cold worked, half hard) versus TF00 (solution heat treated and precipitation hardened). The chemistry is identical, so every difference below comes from the condition. C17200-TF00 is the stronger of the two: yield strength 1,070 MPa (155 ksi) against 585 MPa (84.8 ksi) for C17200-TD02, about 83% more; tensile strength follows at 1,210 MPa (175 ksi) vs 640 MPa (92.8 ksi). In exchange, C17200-TD02 is the more ductile: elongation 15% versus 6% for C17200-TF00, and C17200-TF00 is harder (360 HB vs 190 HB). C17200-TF00 runs hotter in service (200°C vs 150°C continuous) and C17200-TF00 conducts heat better (118 W/m·K vs 105 W/m·K).

C17200-TD02Choose it when the part is bent, formed or impact-loaded.

C17200-TF00Choose it when strength drives the design, or when the part sees heat.

C17200-TD02 vs C17200-TF00: properties

C17200-TD02C17200-TF00

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Shear Modulus

49 GPa7.1 Msi
50 GPa7.3 Msi

Bulk Modulus

107 GPa15.5 Msi
110 GPa16 Msi

Tensile Strength (Ultimate)

640 MPa92.8 ksi
1,210 MPa175 ksi

Yield Strength (0.2% offset)

585 MPa84.8 ksi
1,070 MPa155 ksi

Elongation at Break

15%
6%

Reduction in Area

35%
20%

Shear Strength

410 MPa59.5 ksi
725 MPa105 ksi

Fatigue Strength (Endurance Limit)

230 MPa33.4 ksi
260 MPa37.7 ksi

Charpy V-Notch Impact (RT)

40 J29.5 ft·lbf
7 J5.2 ft·lbf

Hardness, Brinell

190 HB
360 HB

Hardness, Rockwell B

92 HRB
62 HRB

Same in both: Elastic (Young's) Modulus 128 GPa18.6 Msi · Poisson's Ratio 0.3

Physical

Density and transition temperatures.

Density

8.26 g/cm³0.3 lb/in³
8.25 g/cm³0.3 lb/in³

Same in both: Melting Point (Solidus) 865°C1,589 °F · Liquidus Temperature 980°C1,796 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

105 W/m·K60.7 BTU/hr·ft·°F
118 W/m·K68.2 BTU/hr·ft·°F

Max Service Temperature (continuous)

150°C302 °F
200°C392 °F

Min Service Temperature

-250°C-418 °F
-200°C-328 °F

Same in both: Specific Heat Capacity 420 J/kg·K0.1 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 17 µm/m·K9.4 µin/in·°F · Latent Heat of Fusion 205 J/g88.1 BTU/lb

Electrical

Conductivity and insulation.

Electrical Conductivity

17 % IACS
23 % IACS

Electrical Resistivity

1.01×10⁻⁷ Ω·m3.98 µΩ·in
7.5×10⁻⁸ Ω·m2.95 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

65 / 100
68 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.25 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

40 / 100
45 / 100

Machinability Rating (AISI 1212 = 100 %)

20%
55%

Weldability

45 / 100
40 / 100

Formability (cold)

55 / 100
15 / 100

Brazeability / Solderability

80 / 100
60 / 100

Same in both: Castability 50 / 100 · Polishability 85 / 100

Sustainability

Primary-production footprint per kilogram.

Embodied Energy (primary production)

95 MJ/kg40,843 BTU/lb
80 MJ/kg34,394 BTU/lb

Embodied Carbon (primary production)

6.5 kg CO₂/kg
5.5 kg CO₂/kg

Embodied Water

280 L/kg33.6 gal/lb
320 L/kg38.3 gal/lb

Same in both: Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC17200

C17200-TD02 vs C17200-TF00 — frequently asked

Is C17200-TF00 stronger than C17200-TD02?

Yes. C17200-TF00 has a typical yield strength of 1,070 MPa (155 ksi) against 585 MPa (84.8 ksi) for C17200-TD02 — about 83% more. Tensile strength is 1,210 MPa (175 ksi) vs 640 MPa (92.8 ksi).

Which condition does FabDigit quote by default, TD02 or TF00?

A is the default C17200 condition in the FabDigit quote flow (neither TD02 nor TF00). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, C17200-TD02 or C17200-TF00?

C17200-TF00, by a small margin. Both rate fair for machinability — 45/100 against 40/100 for C17200-TD02; for welding the order is C17200-TD02 first (fair, 45/100) then C17200-TF00 (fair, 40/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in C17200-TD02 and C17200-TF00 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.