Copper Alloy C17000-TD04 vs C17000-TH01
Copper Alloy · C17000 temper comparison
C17000-TD04 and C17000-TH01 are two conditions of the same copper alloy grade, C17000: TD04 (solution heat treated and cold worked, full hard) versus TH01 (TD01 and precipitation hardened). The chemistry is identical, so every difference below comes from the condition. C17000-TH01 is the stronger of the two: yield strength 1,050 MPa (152 ksi) against 690 MPa (100 ksi) for C17000-TD04, about 52% more; tensile strength follows at 1,180 MPa (171 ksi) vs 760 MPa (110 ksi). C17000-TH01 is harder — 345 HB against 215 HB for C17000-TD04 — which matters for wear surfaces and threads. C17000-TH01 runs hotter in service (200°C vs 150°C continuous) and C17000-TH01 conducts heat better (107 W/m·K vs 84 W/m·K). On the shop floor, C17000-TD04 welds better (good vs fair) and C17000-TD04 forms better (fair vs poor).
C17000-TD04Choose it when it will be welded.
C17000-TH01Choose it when strength drives the design, or when surface hardness matters.
C17000-TD04 vs C17000-TH01: propertiesHow to read these bars
- One bar per material. A full bar is the highest value among all copper alloy grades in the FabDigit library; each bar is drawn as a share of that.
- The better value (by the usual engineering direction) is in bold. Rows with no direction — density, thermal conductivity — have no bold.
- Values are typical room-temperature figures for the condition named on each card.
- Confirm against the certified mill or resin datasheet before design release.
How to read these bars
- One bar per material. A full bar is the highest value among all copper alloy grades in the FabDigit library; each bar is drawn as a share of that.
- The better value (by the usual engineering direction) is in bold. Rows with no direction — density, thermal conductivity — have no bold.
- Values are typical room-temperature figures for the condition named on each card.
- Confirm against the certified mill or resin datasheet before design release.
Mechanical
Strength, stiffness, ductility and hardness at room temperature.
Elastic (Young's) Modulus
Tensile Strength (Ultimate)
Yield Strength (0.2% offset)
Reduction in Area
Compressive Strength
Shear Strength
Fatigue Strength (Endurance Limit)
Fracture Toughness (K_IC)
Charpy V-Notch Impact (RT)
Hardness, Brinell
Hardness, Rockwell C
Hardness, Vickers
Same in both: Shear Modulus 50 GPa7.3 Msi · Bulk Modulus 115 GPa16.7 Msi · Poisson's Ratio 0.3 · Elongation at Break 5%
Physical
Density and transition temperatures.
Same in both: Density 8.41 g/cm³0.3 lb/in³ · Melting Point (Solidus) 866°C1,591 °F · Liquidus Temperature 980°C1,796 °F
Thermal
How each material carries heat and how hot it can run.
Thermal Conductivity
Max Service Temperature (continuous)
Same in both: Specific Heat Capacity 420 J/kg·K0.1 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 17 µm/m·K9.4 µin/in·°F · Latent Heat of Fusion 200 J/g86 BTU/lb · Min Service Temperature -200°C-328 °F
Electrical
Conductivity and insulation.
Electrical Conductivity
Electrical Resistivity
Chemical & Environmental
Corrosion and environmental resistance (0–100 scores).
Same in both: Galvanic Potential (seawater, vs SCE) -0.2 V · Corrosion Resistance 70 / 100
Manufacturability
FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.
Machinability
Machinability Rating (AISI 1212 = 100 %)
Weldability
Formability (cold)
Same in both: Castability 45 / 100 · Brazeability / Solderability 70 / 100 · Polishability 85 / 100
Sustainability
Primary-production footprint per kilogram.
Same in both: Embodied Energy (primary production) 95 MJ/kg40,843 BTU/lb · Embodied Carbon (primary production) 6.5 kg CO₂/kg · Embodied Water 260 L/kg31.2 gal/lb · Typical Recycled Content 30%
Strength versus weight
Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.
C17000-TD04 vs C17000-TH01 — frequently asked
Is C17000-TH01 stronger than C17000-TD04?
Yes. C17000-TH01 has a typical yield strength of 1,050 MPa (152 ksi) against 690 MPa (100 ksi) for C17000-TD04 — about 52% more. Tensile strength is 1,180 MPa (171 ksi) vs 760 MPa (110 ksi).
Which condition does FabDigit quote by default, TD04 or TH01?
TF00 is the default C17000 condition in the FabDigit quote flow (neither TD04 nor TH01). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.
Which welds better, C17000-TD04 or C17000-TH01?
C17000-TD04. Its weldability rates good (55/100) against fair (45/100) for C17000-TH01.
Ready to make it?
Upload a CAD file and FabDigit prices the part in C17000-TD04 and C17000-TH01 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.
Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.