FabDigitFabDigit

Copper Alloy C15000-TD04 vs C15000-TF00

Copper Alloy · C15000 temper comparison

C15000-TD04 and C15000-TF00 are two conditions of the same copper alloy grade, C15000: TD04 (solution heat treated and cold worked, full hard) versus TF00 (solution heat treated and precipitation hardened). The chemistry is identical, so every difference below comes from the condition. C15000-TD04 is the stronger of the two: yield strength 365 MPa (52.9 ksi) against 195 MPa (28.3 ksi) for C15000-TF00, about 87% more; tensile strength follows at 400 MPa (58 ksi) vs 310 MPa (45 ksi). In exchange, C15000-TF00 is the more ductile: elongation 25% versus 12% for C15000-TD04, and C15000-TD04 is harder (108 HB vs 75 HB). C15000-TF00 runs hotter in service (450°C vs 300°C continuous).

C15000-TD04Choose it when strength drives the design.

C15000-TF00Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

C15000-TD04 vs C15000-TF00: properties

C15000-TD04C15000-TF00

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

400 MPa58 ksi
310 MPa45 ksi

Yield Strength (0.2% offset)

365 MPa52.9 ksi
195 MPa28.3 ksi

Elongation at Break

12%
25%

Shear Strength

250 MPa36.3 ksi
200 MPa29 ksi

Fatigue Strength (Endurance Limit)

135 MPa19.6 ksi
110 MPa16 ksi

Hardness, Brinell

108 HB
75 HB

Hardness, Rockwell B

65 HRB
45 HRB

Hardness, Vickers

118 HV
82 HV

Same in both: Elastic (Young's) Modulus 128 GPa18.6 Msi · Shear Modulus 47.5 GPa6.9 Msi · Bulk Modulus 140 GPa20.3 Msi · Poisson's Ratio 0.34 · Reduction in Area 45% · Compressive Strength 460 MPa66.7 ksi

Physical

Density and transition temperatures.

Same in both: Density 8.89 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,000°C1,832 °F · Liquidus Temperature 1,082°C1,980 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

345 W/m·K199 BTU/hr·ft·°F
367 W/m·K212 BTU/hr·ft·°F

Max Service Temperature (continuous)

300°C572 °F
450°C842 °F

Same in both: Specific Heat Capacity 385 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 17.6 µm/m·K9.8 µin/in·°F · Latent Heat of Fusion 205 J/g88.1 BTU/lb · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

89 % IACS
94 % IACS

Electrical Resistivity

1.94×10⁻⁸ Ω·m0.764 µΩ·in
1.83×10⁻⁸ Ω·m0.72 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.2 V · Corrosion Resistance 55 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

28 / 100
25 / 100

Formability (cold)

35 / 100
60 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 20% · Weldability 40 / 100 · Castability 40 / 100 · Brazeability / Solderability 75 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 57 MJ/kg24,506 BTU/lb · Embodied Carbon (primary production) 3.8 kg CO₂/kg · Embodied Water 250 L/kg30 gal/lb · Typical Recycled Content 20%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC15000

C15000-TD04 vs C15000-TF00 — frequently asked

Is C15000-TD04 stronger than C15000-TF00?

Yes. C15000-TD04 has a typical yield strength of 365 MPa (52.9 ksi) against 195 MPa (28.3 ksi) for C15000-TF00 — about 87% more. Tensile strength is 400 MPa (58 ksi) vs 310 MPa (45 ksi).

Which condition does FabDigit quote by default, TD04 or TF00?

TH04 is the default C15000 condition in the FabDigit quote flow (neither TD04 nor TF00). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C15000-TD04 over C15000-TF00?

Pick C15000-TD04 when strength drives the design. Pick C15000-TF00 when the part is bent, formed or impact-loaded, or when the part sees heat.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C15000-TD04 and C15000-TF00 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.