FabDigitFabDigit

Copper Alloy C14500-H01 vs C14500-M10

Copper Alloy · C14500 temper comparison

C14500-H01 and C14500-M10 are two conditions of the same copper alloy grade, C14500: H01 (quarter hard) versus M10 (as hot forged and air cooled). The chemistry is identical, so every difference below comes from the condition. C14500-H01 is the stronger of the two: yield strength 240 MPa (34.8 ksi) against 69 MPa (10 ksi) for C14500-M10, about 3.5 times as much; tensile strength follows at 285 MPa (41.3 ksi) vs 221 MPa (32.1 ksi). In exchange, C14500-M10 is the more ductile: elongation 40% versus 22% for C14500-H01, and C14500-H01 is harder (78 HB vs 50 HB).

C14500-H01Choose it when strength drives the design.

C14500-M10Choose it when the part is bent, formed or impact-loaded.

C14500-H01 vs C14500-M10: properties

C14500-H01C14500-M10

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

285 MPa41.3 ksi
221 MPa32.1 ksi

Yield Strength (0.2% offset)

240 MPa34.8 ksi
69 MPa10 ksi

Elongation at Break

22%
40%

Shear Strength

185 MPa26.8 ksi
152 MPa22 ksi

Fatigue Strength (Endurance Limit)

90 MPa13.1 ksi
76 MPa11 ksi

Hardness, Brinell

78 HB
50 HB

Hardness, Rockwell B

33 HRB
40 HRB

Same in both: Elastic (Young's) Modulus 117 GPa17 Msi · Shear Modulus 44 GPa6.4 Msi · Bulk Modulus 140 GPa20.3 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Liquidus Temperature

1,065°C1,949 °F
1,075°C1,967 °F

Same in both: Density 8.94 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,051°C1,924 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

350 W/m·K202 BTU/hr·ft·°F
355 W/m·K205 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 385 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 17.6 µm/m·K9.8 µin/in·°F · Latent Heat of Fusion 205 J/g88.1 BTU/lb · Max Service Temperature (continuous) 200°C392 °F · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

92 % IACS
93 % IACS

Electrical Resistivity

1.87×10⁻⁸ Ω·m0.736 µΩ·in
1.85×10⁻⁸ Ω·m0.728 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Galvanic Potential (seawater, vs SCE)

-0.2 V
-0.24 V

Corrosion Resistance

65 / 100
62 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

85 / 100
92 / 100

Weldability

25 / 100
30 / 100

Formability (cold)

50 / 100
75 / 100

Brazeability / Solderability

90 / 100
85 / 100

Same in both: Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Embodied Carbon (primary production)

3.6 kg CO₂/kg
3.8 kg CO₂/kg

Embodied Water

260 L/kg31.2 gal/lb
350 L/kg41.9 gal/lb

Same in both: Embodied Energy (primary production) 57 MJ/kg24,506 BTU/lb · Typical Recycled Content 35%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC14500

C14500-H01 vs C14500-M10 — frequently asked

Is C14500-H01 stronger than C14500-M10?

Yes. C14500-H01 has a typical yield strength of 240 MPa (34.8 ksi) against 69 MPa (10 ksi) for C14500-M10 — about 3.5 times as much. Tensile strength is 285 MPa (41.3 ksi) vs 221 MPa (32.1 ksi).

Which condition does FabDigit quote by default, H01 or M10?

H02 is the default C14500 condition in the FabDigit quote flow (neither H01 nor M10). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, C14500-H01 or C14500-M10?

C14500-M10, by a small margin. Both rate excellent for machinability — 92/100 against 85/100 for C14500-H01; for welding the order is C14500-M10 first (poor, 30/100) then C14500-H01 (poor, 25/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in C14500-H01 and C14500-M10 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.