FabDigitFabDigit

Copper Alloy C1220 1/2H vs C1220-H

Copper Alloy · C1220 temper comparison

C1220 1/2H and C1220-H are two conditions of the same copper alloy grade, C1220: 1/2H (half hard) versus H (hardened). The chemistry is identical, so every difference below comes from the condition. C1220-H is the stronger of the two: yield strength 300 MPa (43.5 ksi) against 250 MPa (36.3 ksi) for C1220 1/2H, about 20% more; tensile strength follows at 345 MPa (50 ksi) vs 305 MPa (44.2 ksi). In exchange, C1220 1/2H is the more ductile: elongation 15% versus 10% for C1220-H, and C1220-H is harder (110 HV vs 95 HV). C1220 1/2H runs hotter in service (200°C vs 150°C continuous).

C1220 1/2HChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

C1220-HChoose it when strength drives the design.

C1220 1/2H vs C1220-H: properties

C1220 1/2HC1220-H

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

305 MPa44.2 ksi
345 MPa50 ksi

Yield Strength (0.2% offset)

250 MPa36.3 ksi
300 MPa43.5 ksi

Elongation at Break

15%
10%

Shear Strength

186 MPa27 ksi
200 MPa29 ksi

Fatigue Strength (Endurance Limit)

95 MPa13.8 ksi
110 MPa16 ksi

Hardness, Vickers

95 HV
110 HV

Same in both: Elastic (Young's) Modulus 117 GPa17 Msi · Shear Modulus 44 GPa6.4 Msi · Bulk Modulus 140 GPa20.3 Msi · Poisson's Ratio 0.34 · Reduction in Area 75% · Charpy V-Notch Impact (RT) 60 J44.3 ft·lbf · Hardness, Brinell 45 HB

Physical

Density and transition temperatures.

Same in both: Density 8.94 g/cm³0.32 lb/in³ · Melting Point (Solidus) 1,065°C1,949 °F · Liquidus Temperature 1,083°C1,981 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

339 W/m·K196 BTU/hr·ft·°F
335 W/m·K194 BTU/hr·ft·°F

Max Service Temperature (continuous)

200°C392 °F
150°C302 °F

Same in both: Specific Heat Capacity 385 J/kg·K0.09 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 17.6 µm/m·K9.8 µin/in·°F · Latent Heat of Fusion 205 J/g88.1 BTU/lb · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Same in both: Electrical Conductivity 84 % IACS · Electrical Resistivity 2.03×10⁻⁸ Ω·m0.799 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.22 V · Corrosion Resistance 68 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability Rating (AISI 1212 = 100 %)

25%
30%

Formability (cold)

60 / 100
40 / 100

Same in both: Machinability 25 / 100 · Weldability 80 / 100 · Castability 40 / 100 · Brazeability / Solderability 100 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 57 MJ/kg24,506 BTU/lb · Embodied Carbon (primary production) 3.8 kg CO₂/kg · Embodied Water 300 L/kg35.9 gal/lb · Typical Recycled Content 35%

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC1220

C1220 1/2H vs C1220-H — frequently asked

Is C1220-H stronger than C1220 1/2H?

Yes. C1220-H has a typical yield strength of 300 MPa (43.5 ksi) against 250 MPa (36.3 ksi) for C1220 1/2H — about 20% more. Tensile strength is 345 MPa (50 ksi) vs 305 MPa (44.2 ksi).

Which condition does FabDigit quote by default, 1/2H or H?

O is the default C1220 condition in the FabDigit quote flow (neither 1/2H nor H). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose C1220 1/2H over C1220-H?

Pick C1220 1/2H when the part is bent, formed or impact-loaded, or when the part sees heat. Pick C1220-H when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C1220 1/2H and C1220-H side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.