FabDigitFabDigit

Copper Alloy C10800 vs C16200

Copper Alloy · grade comparison

Copper Alloy C10800 and C16200 are both copper alloy grades. C16200 is the stronger of the two: yield strength 395 MPa (57.3 ksi) against 69 MPa (10 ksi) for C10800, about 5.7 times as much; tensile strength follows at 435 MPa (63.1 ksi) vs 221 MPa (32.1 ksi). In exchange, C10800 is the more ductile: elongation 45% versus 8% for C16200, and C16200 is harder (115 HB vs 45 HB). C10800 runs hotter in service (250°C vs 200°C continuous) and C10800 conducts heat better (391 W/m·K vs 350 W/m·K). On the shop floor, C10800 welds better (very good vs fair).

C10800Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

C16200Choose it when strength drives the design.

C10800 vs C16200: properties

C10800C16200

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

221 MPa32.1 ksi
435 MPa63.1 ksi

Yield Strength (0.2% offset)

69 MPa10 ksi
395 MPa57.3 ksi

Elongation at Break

45%
8%

Reduction in Area

75%
—

Shear Strength

152 MPa22 ksi
265 MPa38.4 ksi

Fatigue Strength (Endurance Limit)

76 MPa11 ksi
170 MPa24.7 ksi

Hardness, Brinell

45 HB
115 HB

Hardness, Vickers

48 HV
120 HV

Hardness, Rockwell B

—
65 HRB

Same in both: Elastic (Young's) Modulus 117 GPa17 Msi · Shear Modulus 44 GPa6.4 Msi · Bulk Modulus 140 GPa20.3 Msi · Poisson's Ratio 0.34

Physical

Density and transition temperatures.

Melting Point (Solidus)

1,065°C1,949 °F
1,030°C1,886 °F

Liquidus Temperature

1,083°C1,981 °F
1,076°C1,969 °F

Same in both: Density 8.94 g/cm³0.32 lb/in³

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

391 W/m·K226 BTU/hr·ft·°F
350 W/m·K202 BTU/hr·ft·°F

Thermal Expansion (CTE, 20–100 °C)

17.7 µm/m·K9.8 µin/in·°F
17 µm/m·K9.4 µin/in·°F

Max Service Temperature (continuous)

250°C482 °F
200°C392 °F

Min Service Temperature

-269°C-452 °F
-200°C-328 °F

Same in both: Specific Heat Capacity 385 J/kg·K0.09 BTU/lb·°F · Latent Heat of Fusion 205 J/g88.1 BTU/lb

Electrical

Conductivity and insulation.

Electrical Conductivity

98 % IACS
87 % IACS

Electrical Resistivity

1.76×10⁻⁸ Ω·m0.693 µΩ·in
1.98×10⁻⁸ Ω·m0.78 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Galvanic Potential (seawater, vs SCE)

-0.22 V
-0.25 V

Corrosion Resistance

62 / 100
70 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

28 / 100
25 / 100

Weldability

80 / 100
40 / 100

Formability (cold)

95 / 100
40 / 100

Brazeability / Solderability

95 / 100
85 / 100

Polishability

85 / 100
70 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 20%

Sustainability

Primary-production footprint per kilogram.

Embodied Carbon (primary production)

3.6 kg CO₂/kg
3.8 kg CO₂/kg

Typical Recycled Content

15%
30%

Same in both: Embodied Energy (primary production) 57 MJ/kg24,506 BTU/lb · Embodied Water 250 L/kg30 gal/lb

Common Calculations

Ratios derived from the values above.

Specific Strength (UTS / density)

25 kN·m/kg
49 kN·m/kg

Modulus of Resilience

20 kJ/m³
667 kJ/m³

Thermal Diffusivity

113.6 mm²/s
101.7 mm²/s

Thermal Shock Resistance Index

42
77

Same in both: Specific Stiffness (E / density) 13.1 MN·m/kg

Strength versus weight

Yield strength against density for every copper alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,0007.588.599.5Density (g/cm³)Yield strength (MPa) — log scaleC16200C10800

Manufacturing and finishing

CapabilityC10800C16200
Default condition——
Relative cost$$$$ High$$$$ High
Min. machined wall——
Best machined surface——

Both take the same 4 finishes: Copper Plating, Electroless Nickel (EN), Gold Plating, Silver Plating.

C10800 vs C16200 — frequently asked

Is C16200 stronger than C10800?

Yes. C16200 has a typical yield strength of 395 MPa (57.3 ksi) against 69 MPa (10 ksi) for C10800 — about 5.7 times as much. Tensile strength is 435 MPa (63.1 ksi) vs 221 MPa (32.1 ksi).

Which is cheaper, C10800 or C16200?

Both sit in the same relative cost tier ($$$$, high); the part price will be decided by machining time, tolerance and quantity rather than by the material.

Which welds better, C10800 or C16200?

C10800. Its weldability rates very good (80/100) against fair (40/100) for C16200.

Ready to make it?

Upload a CAD file and FabDigit prices the part in C10800 and C16200 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.