FabDigitFabDigit

2124/SiC/25p F vs 2124/SiC/25p T4

Composite · 2124/SiC/25p grade comparison

2124/SiC/25p F and 2124/SiC/25p T4 are two grades of the same composite grade, 2124/SiC/25p: F (as fabricated) versus T4 (solution heat treated and naturally aged). The chemistry is identical, so every difference below comes from the condition. 2124/SiC/25p T4 is the stronger of the two: yield strength 400 MPa (58 ksi) against 330 MPa (47.9 ksi) for 2124/SiC/25p F, about 21% more; tensile strength follows at 560 MPa (81.2 ksi) vs 450 MPa (65.3 ksi). 2124/SiC/25p F runs hotter in service (175°C vs 150°C continuous) and 2124/SiC/25p F conducts heat better (150 W/m·K vs 130 W/m·K).

2124/SiC/25p FChoose it when the part sees heat.

2124/SiC/25p T4Choose it when strength drives the design.

2124/SiC/25p F vs 2124/SiC/25p T4: properties

2124/SiC/25p F2124/SiC/25p T4

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

450 MPa65.3 ksi
560 MPa81.2 ksi

Yield Strength (0.2% offset)

330 MPa47.9 ksi
400 MPa58 ksi

Compressive Strength

520 MPa75.4 ksi
630 MPa91.4 ksi

Flexural Strength

600 MPa87 ksi
740 MPa107 ksi

Shear Strength

270 MPa39.2 ksi
320 MPa46.4 ksi

Fracture Toughness (K_IC)

20 MPa·√m18.2 ksi·√in
19 MPa·√m17.3 ksi·√in

Same in both: Elastic (Young's) Modulus 114 GPa16.5 Msi · Shear Modulus 45 GPa6.5 Msi · Bulk Modulus 90 GPa13.1 Msi · Poisson's Ratio 0.29 · Elongation at Break 5% · Compressive Modulus 116 GPa16.8 Msi · Flexural Modulus 114 GPa16.5 Msi

Physical

Density and transition temperatures.

Same in both: Density 2.88 g/cm³0.1 lb/in³

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

150 W/m·K86.7 BTU/hr·ft·°F
130 W/m·K75.1 BTU/hr·ft·°F

Max Service Temperature (continuous)

175°C347 °F
150°C302 °F

Same in both: Specific Heat Capacity 830 J/kg·K0.2 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 15 µm/m·K8.3 µin/in·°F · Min Service Temperature -196°C-321 °F · Max Service Temperature (short-term) 300°C572 °F

Electrical

Conductivity and insulation.

Electrical Resistivity

5.6×10⁻⁸ Ω·m2.2 µΩ·in
7.2×10⁻⁸ Ω·m2.83 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

30 / 100
28 / 100

Same in both: UV / Weathering Resistance 95 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

14 / 100
13 / 100

Same in both: Polishability 45 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 260 MJ/kg111,780 BTU/lb · Embodied Carbon (primary production) 18 kg CO₂/kg · Embodied Water 1,200 L/kg144 gal/lb · Typical Recycled Content 0%

Strength versus weight

Yield strength against density for every composite grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

1101001,000510Density (g/cm³)Yield strength (MPa) — log scale2124/SiC/25p

2124/SiC/25p F vs 2124/SiC/25p T4 — frequently asked

Is 2124/SiC/25p T4 stronger than 2124/SiC/25p F?

Yes. 2124/SiC/25p T4 has a typical yield strength of 400 MPa (58 ksi) against 330 MPa (47.9 ksi) for 2124/SiC/25p F — about 21% more. Tensile strength is 560 MPa (81.2 ksi) vs 450 MPa (65.3 ksi).

Which grade does FabDigit quote by default, F or T4?

T6 is the default 2124/SiC/25p condition in the FabDigit quote flow (neither F nor T4). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose 2124/SiC/25p F over 2124/SiC/25p T4?

Pick 2124/SiC/25p F when the part sees heat. Pick 2124/SiC/25p T4 when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 2124/SiC/25p F and 2124/SiC/25p T4 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.