Elgiloy-ANN and Elgiloy CW-1/2H are two conditions of the same cobalt-chrome alloy grade, Elgiloy: ANN (annealed) versus CW-1/2H (cold worked ~30–40 %). The chemistry is identical, so every difference below comes from the condition. Elgiloy CW-1/2H is the stronger of the two: yield strength 1,250 MPa (181 ksi) against 480 MPa (69.6 ksi) for Elgiloy-ANN, about 160% more; tensile strength follows at 1,500 MPa (218 ksi) vs 1,000 MPa (145 ksi). In exchange, Elgiloy-ANN is the more ductile: elongation 55% versus 12% for Elgiloy CW-1/2H, and Elgiloy CW-1/2H is harder (45 HRC vs 22 HRC). Elgiloy CW-1/2H is stiffer (200 GPa vs 190 GPa) and Elgiloy-ANN runs hotter in service (500°C vs 350°C continuous). On the shop floor, Elgiloy-ANN welds better (good vs fair).

Elgiloy-ANNChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

Elgiloy CW-1/2HChoose it when strength drives the design.

Elgiloy-ANN vs Elgiloy CW-1/2H: properties

Elgiloy-ANNElgiloy CW-1/2H

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

190 GPa27.6 Msi
200 GPa29 Msi

Tensile Strength (Ultimate)

1,000 MPa145 ksi
1,500 MPa218 ksi

Yield Strength (0.2% offset)

480 MPa69.6 ksi
1,250 MPa181 ksi

Elongation at Break

55%
12%

Reduction in Area

60%
45%

Shear Strength

650 MPa94.3 ksi
900 MPa131 ksi

Fatigue Strength (Endurance Limit)

350 MPa50.8 ksi
500 MPa72.5 ksi

Hardness, Rockwell C

22 HRC
45 HRC

Hardness, Vickers

250 HV
450 HV

Same in both: Shear Modulus 80 GPa11.6 Msi · Bulk Modulus 175 GPa25.4 Msi · Poisson's Ratio 0.3

Physical

Density and transition temperatures.

Same in both: Density 8.3 g/cm³0.3 lb/in³ · Melting Point (Solidus) 1,400°C2,552 °F · Liquidus Temperature 1,450°C2,642 °F

Thermal

How each material carries heat and how hot it can run.

Max Service Temperature (continuous)

500°C932 °F
350°C662 °F

Same in both: Thermal Conductivity 12.5 W/m·K7.2 BTU/hr·ft·°F · Specific Heat Capacity 430 J/kg·K0.1 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 15 µm/m·K8.3 µin/in·°F · Latent Heat of Fusion 280 J/g120 BTU/lb · Min Service Temperature -269°C-452 °F

Electrical

Conductivity and insulation.

Electrical Resistivity

1×10⁻⁶ Ω·m39.4 µΩ·in
1.02×10⁻⁶ Ω·m40.2 µΩ·in

Same in both: Electrical Conductivity 1.7 % IACS

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.2 V · Corrosion Resistance 88 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

20 / 100
17 / 100

Weldability

55 / 100
40 / 100

Formability (cold)

70 / 100
45 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 12% · Castability 25 / 100 · Brazeability / Solderability 55 / 100 · Polishability 85 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 165 MJ/kg70,937 BTU/lb · Embodied Carbon (primary production) 13 kg CO₂/kg · Embodied Water 500 L/kg59.9 gal/lb · Typical Recycled Content 20%

Strength versus weight

Yield strength against density for every cobalt-chrome alloy grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

5007001,0001,5002,0008.28.48.68.89Density (g/cm³)Yield strength (MPa) — log scaleElgiloy

Elgiloy-ANN vs Elgiloy CW-1/2H — frequently asked

Is Elgiloy CW-1/2H stronger than Elgiloy-ANN?

Yes. Elgiloy CW-1/2H has a typical yield strength of 1,250 MPa (181 ksi) against 480 MPa (69.6 ksi) for Elgiloy-ANN — about 160% more. Tensile strength is 1,500 MPa (218 ksi) vs 1,000 MPa (145 ksi).

Which condition does FabDigit quote by default, ANN or CW-1/2H?

CWA is the default Elgiloy condition in the FabDigit quote flow (neither ANN nor CW-1/2H). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which welds better, Elgiloy-ANN or Elgiloy CW-1/2H?

Elgiloy-ANN. Its weldability rates good (55/100) against fair (40/100) for Elgiloy CW-1/2H.

Ready to make it?

Upload a CAD file and FabDigit prices the part in Elgiloy-ANN and Elgiloy CW-1/2H side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.