FabDigitFabDigit

PZT vs Z5U

Ceramic · grade comparison

PZT and Z5U are both ceramic grades. PZT is the stronger of the two: tensile strength 75 MPa (10.9 ksi) against 50 MPa (7.25 ksi) for Z5U, about 50% more. Z5U is harder — 550 HV against 350 HV for PZT — which matters for wear surfaces and threads. Z5U is lighter (5.6 g/cm³ vs 7.75 g/cm³ for PZT) and Z5U is stiffer (110 GPa vs 61 GPa).

PZTChoose it when strength drives the design, or when the part sees heat.

Z5UChoose it when surface hardness matters, or when weight is the constraint.

PZT vs Z5U: properties

PZTZ5U

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

61 GPa8.8 Msi
110 GPa16 Msi

Shear Modulus

23 GPa3.3 Msi
44 GPa6.4 Msi

Bulk Modulus

55 GPa8 Msi
92 GPa13.3 Msi

Poisson's Ratio

0.31
0.28

Tensile Strength (Ultimate)

75 MPa10.9 ksi
50 MPa7.3 ksi

Compressive Strength

600 MPa87 ksi
550 MPa79.8 ksi

Flexural Strength

85 MPa12.3 ksi
110 MPa16 ksi

Hardness, Vickers

350 HV
550 HV

Hardness, Knoop

330 HK
—

Hardness, Mohs

5
6

Elongation at Break

—
0%

Shear Strength

—
70 MPa10.2 ksi

Same in both: Fracture Toughness (K_IC) 1 MPa·√m0.91 ksi·√in

Physical

Density and transition temperatures.

Density

7.75 g/cm³0.28 lb/in³
5.6 g/cm³0.2 lb/in³

Porosity

1%
3%

Melting Point (Solidus)

—
1,618°C2,944 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

1.3 W/m·K0.75 BTU/hr·ft·°F
2.8 W/m·K1.6 BTU/hr·ft·°F

Specific Heat Capacity

380 J/kg·K0.09 BTU/lb·°F
440 J/kg·K0.11 BTU/lb·°F

Thermal Expansion (CTE, 20–100 °C)

4 µm/m·K2.2 µin/in·°F
10 µm/m·K5.6 µin/in·°F

Max Service Temperature (continuous)

175°C347 °F
85°C185 °F

Min Service Temperature

-50°C-58 °F
10°C50 °F

Electrical

Conductivity and insulation.

Electrical Resistivity

1×10¹⁰ Ω·m3.94×10¹⁷ µΩ·in
1×10¹¹ Ω·m3.94×10¹⁸ µΩ·in

Dielectric Strength

5 kV/mm127 V/mil
14 kV/mm356 V/mil

Dielectric Constant (1 MHz)

1,700
5,500

Dissipation Factor (1 MHz)

0.02
0.035

Volume Resistivity

1×10¹² Ω·cm
1×10¹³ Ω·cm

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

60 / 100
85 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

8 / 100
5 / 100

Polishability

70 / 100
60 / 100

Sintering / Firing Temperature

1,250°C2,282 °F
1,150°C2,102 °F

Sustainability

Primary-production footprint per kilogram.

Embodied Energy (primary production)

70 MJ/kg30,095 BTU/lb
85 MJ/kg36,543 BTU/lb

Embodied Carbon (primary production)

5.5 kg CO₂/kg
6.5 kg CO₂/kg

Embodied Water

60 L/kg7.2 gal/lb
250 L/kg30 gal/lb

Typical Recycled Content

5%
0%

Common Calculations

Ratios derived from the values above.

Specific Strength (UTS / density)

10 kN·m/kg
9 kN·m/kg

Specific Stiffness (E / density)

7.9 MN·m/kg
19.6 MN·m/kg

Thermal Diffusivity

0.4 mm²/s
1.1 mm²/s

Same in both: Thermal Shock Resistance Index 0

Strength versus weight

Yield strength against density for every ceramic grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

501002005001,000234567Density (g/cm³)Yield strength (MPa) — log scalePZT

Manufacturing and finishing

CapabilityPZTZ5U
Default condition——
Relative cost$$$$ High$$$$ High
Min. machined wall——
Best machined surface——

PZT vs Z5U — frequently asked

Is PZT stronger than Z5U?

Yes. PZT has a typical tensile strength of 75 MPa (10.9 ksi) against 50 MPa (7.25 ksi) for Z5U — about 50% more.

Which is cheaper, PZT or Z5U?

Both sit in the same relative cost tier ($$$$, high); the part price will be decided by machining time, tolerance and quantity rather than by the material.

When should I choose PZT over Z5U?

Pick PZT when strength drives the design, or when the part sees heat. Pick Z5U when surface hardness matters, or when weight is the constraint.

Ready to make it?

Upload a CAD file and FabDigit prices the part in PZT and Z5U side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.