FabDigitFabDigit

Aluminum ZL201A-F vs ZL201A-T7

Aluminum · ZL201A temper comparison

ZL201A-F and ZL201A-T7 are two conditions of the same aluminum grade, ZL201A: F (as fabricated) versus T7 (solution heat treated and overaged (stabilized)). The chemistry is identical, so every difference below comes from the condition. ZL201A-T7 is the stronger of the two: yield strength 265 MPa (38.4 ksi) against 95 MPa (13.8 ksi) for ZL201A-F, about 179% more; tensile strength follows at 345 MPa (50 ksi) vs 165 MPa (23.9 ksi). ZL201A-T7 is the more ductile: elongation 4% versus 3% for ZL201A-F, and ZL201A-T7 is harder (95 HB vs 60 HB). ZL201A-T7 runs hotter in service (300°C vs 150°C continuous). On the shop floor, ZL201A-T7 machines more easily (very good vs good).

ZL201A-T7Choose it when strength drives the design, or when the part is bent, formed or impact-loaded.

ZL201A-F vs ZL201A-T7: properties

ZL201A-FZL201A-T7

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

69 GPa10 Msi
70 GPa10.2 Msi

Tensile Strength (Ultimate)

165 MPa23.9 ksi
345 MPa50 ksi

Yield Strength (0.2% offset)

95 MPa13.8 ksi
265 MPa38.4 ksi

Elongation at Break

3%
4%

Compressive Strength

105 MPa15.2 ksi
275 MPa39.9 ksi

Shear Strength

110 MPa16 ksi
215 MPa31.2 ksi

Fatigue Strength (Endurance Limit)

55 MPa8 ksi
90 MPa13.1 ksi

Fracture Toughness (K_IC)

18 MPa·√m16.4 ksi·√in
31 MPa·√m28.2 ksi·√in

Charpy V-Notch Impact (RT)

4 J3 ft·lbf
15 J11.1 ft·lbf

Hardness, Brinell

60 HB
95 HB

Same in both: Shear Modulus 26.5 GPa3.8 Msi · Bulk Modulus 72 GPa10.4 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.83 g/cm³0.1 lb/in³ · Melting Point (Solidus) 547°C1,017 °F · Liquidus Temperature 648°C1,198 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

145 W/m·K83.8 BTU/hr·ft·°F
140 W/m·K80.9 BTU/hr·ft·°F

Max Service Temperature (continuous)

150°C302 °F
300°C572 °F

Same in both: Specific Heat Capacity 880 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 22.5 µm/m·K12.5 µin/in·°F · Latent Heat of Fusion 390 J/g168 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

36 % IACS
34 % IACS

Electrical Resistivity

4.8×10⁻⁸ Ω·m1.89 µΩ·in
5.1×10⁻⁸ Ω·m2.01 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

28 / 100
34 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.69 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

60 / 100
70 / 100

Machinability Rating (AISI 1212 = 100 %)

200%
290%

Weldability

30 / 100
35 / 100

Formability (cold)

8 / 100
10 / 100

Same in both: Castability 45 / 100 · Brazeability / Solderability 25 / 100 · Polishability 55 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 205 MJ/kg88,134 BTU/lb · Embodied Carbon (primary production) 12.5 kg CO₂/kg · Embodied Water 1,200 L/kg144 gal/lb · Typical Recycled Content 10%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scaleZL201A

ZL201A-F vs ZL201A-T7 — frequently asked

Is ZL201A-T7 stronger than ZL201A-F?

Yes. ZL201A-T7 has a typical yield strength of 265 MPa (38.4 ksi) against 95 MPa (13.8 ksi) for ZL201A-F — about 179% more. Tensile strength is 345 MPa (50 ksi) vs 165 MPa (23.9 ksi).

Which condition does FabDigit quote by default, F or T7?

T5 is the default ZL201A condition in the FabDigit quote flow (neither F nor T7). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, ZL201A-F or ZL201A-T7?

ZL201A-T7. Its machinability rates very good (70/100) against good (60/100) for ZL201A-F; for welding the order is ZL201A-T7 first (fair, 35/100) then ZL201A-F (poor, 30/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in ZL201A-F and ZL201A-T7 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.