Aluminum ZL201-T5 vs ZL201-T7

Aluminum · ZL201 temper comparison

ZL201-T5 and ZL201-T7 are two conditions of the same aluminum grade, ZL201: T5 (cooled from hot working and artificially aged) versus T7 (solution heat treated and overaged (stabilized)). The chemistry is identical, so every difference below comes from the condition. ZL201-T5 is the stronger of the two: tensile strength 350 MPa (50.8 ksi) against 330 MPa (47.9 ksi) for ZL201-T7, about 6% more. ZL201-T5 is the more ductile: elongation 6% versus 3% for ZL201-T7, and ZL201-T5 is harder (90 HB vs 82 HB). ZL201-T7 runs hotter in service (250°C vs 200°C continuous).

ZL201-T5Choose it when strength drives the design, or when the part is bent, formed or impact-loaded.

ZL201-T7Choose it when the part sees heat.

ZL201-T5 vs ZL201-T7: properties

ZL201-T5ZL201-T7

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

350 MPa50.8 ksi
330 MPa47.9 ksi

Yield Strength (0.2% offset)

255 MPa37 ksi
265 MPa38.4 ksi

Elongation at Break

6%
3%

Shear Strength

215 MPa31.2 ksi
205 MPa29.7 ksi

Fatigue Strength (Endurance Limit)

90 MPa13.1 ksi
88 MPa12.8 ksi

Charpy V-Notch Impact (RT)

8 J5.9 ft·lbf
6 J4.4 ft·lbf

Hardness, Brinell

90 HB
82 HB

Same in both: Elastic (Young's) Modulus 70 GPa10.2 Msi · Shear Modulus 26 GPa3.8 Msi · Bulk Modulus 71 GPa10.3 Msi · Poisson's Ratio 0.33 · Compressive Strength 270 MPa39.2 ksi · Fracture Toughness (K_IC) 27 MPa·√m24.6 ksi·√in

Physical

Density and transition temperatures.

Same in both: Density 2.83 g/cm³0.1 lb/in³ · Melting Point (Solidus) 545°C1,013 °F · Liquidus Temperature 650°C1,202 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

130 W/m·K75.1 BTU/hr·ft·°F
140 W/m·K80.9 BTU/hr·ft·°F

Max Service Temperature (continuous)

200°C392 °F
250°C482 °F

Same in both: Specific Heat Capacity 880 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 22.5 µm/m·K12.5 µin/in·°F · Latent Heat of Fusion 390 J/g168 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

33 % IACS
36 % IACS

Same in both: Electrical Resistivity 5.2×10⁻⁸ Ω·m2.05 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

35 / 100
40 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.68 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Same in both: Machinability 75 / 100 · Machinability Rating (AISI 1212 = 100 %) 300% · Weldability 25 / 100 · Formability (cold) 10 / 100 · Castability 35 / 100 · Brazeability / Solderability 15 / 100 · Polishability 55 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 195 MJ/kg83,835 BTU/lb · Embodied Carbon (primary production) 12.5 kg CO₂/kg · Embodied Water 1,150 L/kg138 gal/lb · Typical Recycled Content 15%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scaleZL201

ZL201-T5 vs ZL201-T7 — frequently asked

Is ZL201-T5 stronger than ZL201-T7?

Yes. ZL201-T5 has a typical tensile strength of 350 MPa (50.8 ksi) against 330 MPa (47.9 ksi) for ZL201-T7 — about 6% more.

Which condition does FabDigit quote by default, T5 or T7?

T5 is the default ZL201 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose ZL201-T5 over ZL201-T7?

Pick ZL201-T5 when strength drives the design, or when the part is bent, formed or impact-loaded. Pick ZL201-T7 when the part sees heat.

Ready to make it?

Upload a CAD file and FabDigit prices the part in ZL201-T5 and ZL201-T7 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.