FabDigitFabDigit

Aluminum ZL201-F vs ZL201-T4

Aluminum · ZL201 temper comparison

ZL201-F and ZL201-T4 are two conditions of the same aluminum grade, ZL201: F (as fabricated) versus T4 (solution heat treated and naturally aged). The chemistry is identical, so every difference below comes from the condition. ZL201-T4 is the stronger of the two: yield strength 185 MPa (26.8 ksi) against 110 MPa (16 ksi) for ZL201-F, about 68% more; tensile strength follows at 320 MPa (46.4 ksi) vs 195 MPa (28.3 ksi). ZL201-T4 is the more ductile: elongation 10% versus 5% for ZL201-F, and ZL201-T4 is harder (72 HB vs 60 HB). ZL201-F runs hotter in service (150°C vs 120°C continuous) and ZL201-F conducts heat better (145 W/m·K vs 122 W/m·K).

ZL201-FChoose it when the part sees heat.

ZL201-T4Choose it when strength drives the design, or when the part is bent, formed or impact-loaded.

ZL201-F vs ZL201-T4: properties

ZL201-FZL201-T4

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

195 MPa28.3 ksi
320 MPa46.4 ksi

Yield Strength (0.2% offset)

110 MPa16 ksi
185 MPa26.8 ksi

Elongation at Break

5%
10%

Compressive Strength

150 MPa21.8 ksi
270 MPa39.2 ksi

Shear Strength

125 MPa18.1 ksi
195 MPa28.3 ksi

Fatigue Strength (Endurance Limit)

60 MPa8.7 ksi
85 MPa12.3 ksi

Fracture Toughness (K_IC)

20 MPa·√m18.2 ksi·√in
30 MPa·√m27.3 ksi·√in

Charpy V-Notch Impact (RT)

4 J3 ft·lbf
12 J8.9 ft·lbf

Hardness, Brinell

60 HB
72 HB

Same in both: Elastic (Young's) Modulus 70 GPa10.2 Msi · Shear Modulus 26 GPa3.8 Msi · Bulk Modulus 71 GPa10.3 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.83 g/cm³0.1 lb/in³ · Melting Point (Solidus) 545°C1,013 °F · Liquidus Temperature 650°C1,202 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

145 W/m·K83.8 BTU/hr·ft·°F
122 W/m·K70.5 BTU/hr·ft·°F

Max Service Temperature (continuous)

150°C302 °F
120°C248 °F

Same in both: Specific Heat Capacity 880 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 22.5 µm/m·K12.5 µin/in·°F · Latent Heat of Fusion 390 J/g168 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

38 % IACS
31 % IACS

Electrical Resistivity

4.5×10⁻⁸ Ω·m1.77 µΩ·in
5.2×10⁻⁸ Ω·m2.05 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

32 / 100
35 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.68 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

65 / 100
70 / 100

Machinability Rating (AISI 1212 = 100 %)

250%
300%

Weldability

30 / 100
25 / 100

Formability (cold)

5 / 100
10 / 100

Same in both: Castability 35 / 100 · Brazeability / Solderability 15 / 100 · Polishability 55 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 195 MJ/kg83,835 BTU/lb · Embodied Carbon (primary production) 12.5 kg CO₂/kg · Embodied Water 1,150 L/kg138 gal/lb · Typical Recycled Content 15%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scaleZL201

ZL201-F vs ZL201-T4 — frequently asked

Is ZL201-T4 stronger than ZL201-F?

Yes. ZL201-T4 has a typical yield strength of 185 MPa (26.8 ksi) against 110 MPa (16 ksi) for ZL201-F — about 68% more. Tensile strength is 320 MPa (46.4 ksi) vs 195 MPa (28.3 ksi).

Which condition does FabDigit quote by default, F or T4?

T5 is the default ZL201 condition in the FabDigit quote flow (neither F nor T4). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, ZL201-F or ZL201-T4?

ZL201-T4. Its machinability rates very good (70/100) against good (65/100) for ZL201-F; for welding the order is ZL201-F first (poor, 30/100) then ZL201-T4 (poor, 25/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in ZL201-F and ZL201-T4 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.