FabDigitFabDigit

Aluminum ZL116-F vs ZL116-T5

Aluminum · ZL116 temper comparison

ZL116-F and ZL116-T5 are two conditions of the same aluminum grade, ZL116: F (as fabricated) versus T5 (cooled from hot working and artificially aged). The chemistry is identical, so every difference below comes from the condition. ZL116-T5 is the stronger of the two: yield strength 255 MPa (37 ksi) against 110 MPa (16 ksi) for ZL116-F, about 132% more; tensile strength follows at 335 MPa (48.6 ksi) vs 195 MPa (28.3 ksi). ZL116-T5 is harder — 90 HB against 60 HB for ZL116-F — which matters for wear surfaces and threads.

ZL116-T5Choose it when strength drives the design, or when surface hardness matters.

ZL116-F vs ZL116-T5: properties

ZL116-FZL116-T5

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

70 GPa10.2 Msi
71 GPa10.3 Msi

Tensile Strength (Ultimate)

195 MPa28.3 ksi
335 MPa48.6 ksi

Yield Strength (0.2% offset)

110 MPa16 ksi
255 MPa37 ksi

Compressive Strength

125 MPa18.1 ksi
270 MPa39.2 ksi

Shear Strength

125 MPa18.1 ksi
215 MPa31.2 ksi

Fatigue Strength (Endurance Limit)

65 MPa9.4 ksi
90 MPa13.1 ksi

Fracture Toughness (K_IC)

18 MPa·√m16.4 ksi·√in
20 MPa·√m18.2 ksi·√in

Charpy V-Notch Impact (RT)

6 J4.4 ft·lbf
8 J5.9 ft·lbf

Hardness, Brinell

60 HB
90 HB

Same in both: Shear Modulus 26.5 GPa3.8 Msi · Bulk Modulus 71 GPa10.3 Msi · Poisson's Ratio 0.33 · Elongation at Break 4%

Physical

Density and transition temperatures.

Same in both: Density 2.65 g/cm³0.1 lb/in³ · Melting Point (Solidus) 555°C1,031 °F · Liquidus Temperature 610°C1,130 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

155 W/m·K89.6 BTU/hr·ft·°F
150 W/m·K86.7 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 963 J/kg·K0.23 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 21.5 µm/m·K11.9 µin/in·°F · Latent Heat of Fusion 425 J/g183 BTU/lb · Max Service Temperature (continuous) 150°C302 °F · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

40 % IACS
38 % IACS

Electrical Resistivity

4.3×10⁻⁸ Ω·m1.69 µΩ·in
4.5×10⁻⁸ Ω·m1.77 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

58 / 100
62 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.83 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

50 / 100
55 / 100

Machinability Rating (AISI 1212 = 100 %)

110%
120%

Formability (cold)

8 / 100
10 / 100

Same in both: Weldability 70 / 100 · Castability 88 / 100 · Brazeability / Solderability 35 / 100 · Polishability 45 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 195 MJ/kg83,835 BTU/lb · Embodied Carbon (primary production) 12.5 kg CO₂/kg · Embodied Water 1,200 L/kg144 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scaleZL116

ZL116-F vs ZL116-T5 — frequently asked

Is ZL116-T5 stronger than ZL116-F?

Yes. ZL116-T5 has a typical yield strength of 255 MPa (37 ksi) against 110 MPa (16 ksi) for ZL116-F — about 132% more. Tensile strength is 335 MPa (48.6 ksi) vs 195 MPa (28.3 ksi).

Which condition does FabDigit quote by default, F or T5?

T5 is the default ZL116 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, ZL116-F or ZL116-T5?

ZL116-T5. Its machinability rates good (55/100) against fair (50/100) for ZL116-F.

Ready to make it?

Upload a CAD file and FabDigit prices the part in ZL116-F and ZL116-T5 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.