FabDigitFabDigit

Aluminum ZL114A-T4 vs ZL114A-T5

Aluminum · ZL114A temper comparison

ZL114A-T4 and ZL114A-T5 are two conditions of the same aluminum grade, ZL114A: T4 (solution heat treated and naturally aged) versus T5 (cooled from hot working and artificially aged). The chemistry is identical, so every difference below comes from the condition. ZL114A-T5 is the stronger of the two: yield strength 230 MPa (33.4 ksi) against 130 MPa (18.9 ksi) for ZL114A-T4, about 77% more; tensile strength follows at 300 MPa (43.5 ksi) vs 250 MPa (36.3 ksi). In exchange, ZL114A-T4 is the more ductile: elongation 10% versus 2.5% for ZL114A-T5, and ZL114A-T5 is harder (88 HB vs 65 HB). ZL114A-T5 runs hotter in service (150°C vs 120°C continuous) and ZL114A-T5 conducts electricity better (41 % IACS vs 36 % IACS).

ZL114A-T4Choose it when the part is bent, formed or impact-loaded.

ZL114A-T5Choose it when strength drives the design, or when the part sees heat.

ZL114A-T4 vs ZL114A-T5: properties

ZL114A-T4ZL114A-T5

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

250 MPa36.3 ksi
300 MPa43.5 ksi

Yield Strength (0.2% offset)

130 MPa18.9 ksi
230 MPa33.4 ksi

Elongation at Break

10%
2.5%

Compressive Strength

135 MPa19.6 ksi
285 MPa41.3 ksi

Shear Strength

170 MPa24.7 ksi
205 MPa29.7 ksi

Fatigue Strength (Endurance Limit)

70 MPa10.2 ksi
80 MPa11.6 ksi

Fracture Toughness (K_IC)

32 MPa·√m29.1 ksi·√in
25 MPa·√m22.8 ksi·√in

Hardness, Brinell

65 HB
88 HB

Same in both: Elastic (Young's) Modulus 72 GPa10.4 Msi · Shear Modulus 27 GPa3.9 Msi · Bulk Modulus 71 GPa10.3 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.67 g/cm³0.1 lb/in³ · Melting Point (Solidus) 555°C1,031 °F · Liquidus Temperature 613°C1,135 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

145 W/m·K83.8 BTU/hr·ft·°F
158 W/m·K91.3 BTU/hr·ft·°F

Max Service Temperature (continuous)

120°C248 °F
150°C302 °F

Same in both: Specific Heat Capacity 963 J/kg·K0.23 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 21.5 µm/m·K11.9 µin/in·°F · Latent Heat of Fusion 389 J/g167 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

36 % IACS
41 % IACS

Electrical Resistivity

4.8×10⁻⁸ Ω·m1.89 µΩ·in
4.4×10⁻⁸ Ω·m1.73 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

62 / 100
60 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.83 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

50 / 100
53 / 100

Machinability Rating (AISI 1212 = 100 %)

55%
60%

Formability (cold)

20 / 100
15 / 100

Same in both: Weldability 75 / 100 · Castability 92 / 100 · Brazeability / Solderability 35 / 100 · Polishability 55 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 195 MJ/kg83,835 BTU/lb · Embodied Carbon (primary production) 12 kg CO₂/kg · Embodied Water 1,150 L/kg138 gal/lb · Typical Recycled Content 15%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scaleZL114A

ZL114A-T4 vs ZL114A-T5 — frequently asked

Is ZL114A-T5 stronger than ZL114A-T4?

Yes. ZL114A-T5 has a typical yield strength of 230 MPa (33.4 ksi) against 130 MPa (18.9 ksi) for ZL114A-T4 — about 77% more. Tensile strength is 300 MPa (43.5 ksi) vs 250 MPa (36.3 ksi).

Which condition does FabDigit quote by default, T4 or T5?

T6 is the default ZL114A condition in the FabDigit quote flow (neither T4 nor T5). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose ZL114A-T4 over ZL114A-T5?

Pick ZL114A-T4 when the part is bent, formed or impact-loaded. Pick ZL114A-T5 when strength drives the design, or when the part sees heat.

Ready to make it?

Upload a CAD file and FabDigit prices the part in ZL114A-T4 and ZL114A-T5 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.