FabDigitFabDigit

Aluminum ZL108-F vs ZL108-T6

Aluminum · ZL108 temper comparison

ZL108-F and ZL108-T6 are two conditions of the same aluminum grade, ZL108: F (as fabricated) versus T6 (solution heat treated and artificially aged). The chemistry is identical, so every difference below comes from the condition. ZL108-T6 is the stronger of the two: yield strength 230 MPa (33.4 ksi) against 130 MPa (18.9 ksi) for ZL108-F, about 77% more; tensile strength follows at 265 MPa (38.4 ksi) vs 175 MPa (25.4 ksi). In exchange, ZL108-F is the more ductile: elongation 1% versus 0.7% for ZL108-T6, and ZL108-T6 is harder (105 HB vs 80 HB). ZL108-T6 runs hotter in service (250°C vs 200°C continuous) and ZL108-F conducts heat better (135 W/m·K vs 121 W/m·K).

ZL108-FChoose it when the part is bent, formed or impact-loaded.

ZL108-T6Choose it when strength drives the design, or when the part sees heat.

ZL108-F vs ZL108-T6: properties

ZL108-FZL108-T6

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

78 GPa11.3 Msi
79 GPa11.5 Msi

Tensile Strength (Ultimate)

175 MPa25.4 ksi
265 MPa38.4 ksi

Yield Strength (0.2% offset)

130 MPa18.9 ksi
230 MPa33.4 ksi

Elongation at Break

1%
0.7%

Shear Strength

120 MPa17.4 ksi
195 MPa28.3 ksi

Fatigue Strength (Endurance Limit)

70 MPa10.2 ksi
90 MPa13.1 ksi

Fracture Toughness (K_IC)

12 MPa·√m10.9 ksi·√in
15 MPa·√m13.7 ksi·√in

Charpy V-Notch Impact (RT)

2 J1.5 ft·lbf
3 J2.2 ft·lbf

Hardness, Brinell

80 HB
105 HB

Same in both: Shear Modulus 29 GPa4.2 Msi · Bulk Modulus 76 GPa11 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.68 g/cm³0.1 lb/in³ · Melting Point (Solidus) 516°C961 °F · Liquidus Temperature 566°C1,051 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

135 W/m·K78 BTU/hr·ft·°F
121 W/m·K69.9 BTU/hr·ft·°F

Max Service Temperature (continuous)

200°C392 °F
250°C482 °F

Same in both: Specific Heat Capacity 963 J/kg·K0.23 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 19.5 µm/m·K10.8 µin/in·°F · Latent Heat of Fusion 389 J/g167 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

30 % IACS
27 % IACS

Electrical Resistivity

5.75×10⁻⁸ Ω·m2.26 µΩ·in
6.4×10⁻⁸ Ω·m2.52 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.78 V · Corrosion Resistance 42 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

35 / 100
38 / 100

Machinability Rating (AISI 1212 = 100 %)

32%
35%

Same in both: Weldability 40 / 100 · Formability (cold) 5 / 100 · Castability 92 / 100 · Brazeability / Solderability 30 / 100 · Polishability 40 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12 kg CO₂/kg · Embodied Water 1,100 L/kg132 gal/lb · Typical Recycled Content 60%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scaleZL108

ZL108-F vs ZL108-T6 — frequently asked

Is ZL108-T6 stronger than ZL108-F?

Yes. ZL108-T6 has a typical yield strength of 230 MPa (33.4 ksi) against 130 MPa (18.9 ksi) for ZL108-F — about 77% more. Tensile strength is 265 MPa (38.4 ksi) vs 175 MPa (25.4 ksi).

Which condition does FabDigit quote by default, F or T6?

T6 is the default ZL108 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose ZL108-F over ZL108-T6?

Pick ZL108-F when the part is bent, formed or impact-loaded. Pick ZL108-T6 when strength drives the design, or when the part sees heat.

Ready to make it?

Upload a CAD file and FabDigit prices the part in ZL108-F and ZL108-T6 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.