FabDigitFabDigit

Aluminum ZL105-F vs ZL105-T6

Aluminum · ZL105 temper comparison

ZL105-F and ZL105-T6 are two conditions of the same aluminum grade, ZL105: F (as fabricated) versus T6 (solution heat treated and artificially aged). The chemistry is identical, so every difference below comes from the condition. ZL105-T6 is the stronger of the two: yield strength 200 MPa (29 ksi) against 90 MPa (13.1 ksi) for ZL105-F, about 122% more; tensile strength follows at 265 MPa (38.4 ksi) vs 160 MPa (23.2 ksi). In exchange, ZL105-F is the more ductile: elongation 2.5% versus 2% for ZL105-T6, and ZL105-T6 is harder (85 HB vs 55 HB). On the shop floor, ZL105-T6 machines more easily (good vs fair).

ZL105-FChoose it when the part is bent, formed or impact-loaded.

ZL105-T6Choose it when strength drives the design, or when the part is machined in volume.

ZL105-F vs ZL105-T6: properties

ZL105-FZL105-T6

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

160 MPa23.2 ksi
265 MPa38.4 ksi

Yield Strength (0.2% offset)

90 MPa13.1 ksi
200 MPa29 ksi

Elongation at Break

2.5%
2%

Shear Strength

130 MPa18.9 ksi
195 MPa28.3 ksi

Fatigue Strength (Endurance Limit)

50 MPa7.3 ksi
62 MPa9 ksi

Hardness, Brinell

55 HB
85 HB

Same in both: Elastic (Young's) Modulus 71 GPa10.3 Msi · Shear Modulus 26.5 GPa3.8 Msi · Bulk Modulus 72 GPa10.4 Msi · Poisson's Ratio 0.33 · Fracture Toughness (K_IC) 20 MPa·√m18.2 ksi·√in · Charpy V-Notch Impact (RT) 4 J3 ft·lbf

Physical

Density and transition temperatures.

Same in both: Density 2.71 g/cm³0.1 lb/in³ · Melting Point (Solidus) 546°C1,015 °F · Liquidus Temperature 621°C1,150 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

147 W/m·K84.9 BTU/hr·ft·°F
151 W/m·K87.2 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 963 J/kg·K0.23 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 22.4 µm/m·K12.4 µin/in·°F · Latent Heat of Fusion 389 J/g167 BTU/lb · Max Service Temperature (continuous) 150°C302 °F · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

33 % IACS
36 % IACS

Same in both: Electrical Resistivity 4.79×10⁻⁸ Ω·m1.89 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.78 V · Corrosion Resistance 45 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

45 / 100
60 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 70% · Weldability 55 / 100 · Formability (cold) 5 / 100 · Castability 85 / 100 · Brazeability / Solderability 25 / 100 · Polishability 45 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12.5 kg CO₂/kg · Embodied Water 1,100 L/kg132 gal/lb · Typical Recycled Content 70%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scaleZL105

ZL105-F vs ZL105-T6 — frequently asked

Is ZL105-T6 stronger than ZL105-F?

Yes. ZL105-T6 has a typical yield strength of 200 MPa (29 ksi) against 90 MPa (13.1 ksi) for ZL105-F — about 122% more. Tensile strength is 265 MPa (38.4 ksi) vs 160 MPa (23.2 ksi).

Which condition does FabDigit quote by default, F or T6?

T6 is the default ZL105 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, ZL105-F or ZL105-T6?

ZL105-T6. Its machinability rates good (60/100) against fair (45/100) for ZL105-F.

Ready to make it?

Upload a CAD file and FabDigit prices the part in ZL105-F and ZL105-T6 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.