Aluminum LM25-T6 vs LM25-TB7

Aluminum · LM25 temper comparison

LM25-T6 and LM25-TB7 are two conditions of the same aluminum grade, LM25: T6 (solution heat treated and artificially aged) versus TB7 (solution heat treated and stabilised). The chemistry is identical, so every difference below comes from the condition. LM25-T6 is the stronger of the two: yield strength 215 MPa (31.2 ksi) against 105 MPa (15.2 ksi) for LM25-TB7, about 105% more; tensile strength follows at 250 MPa (36.3 ksi) vs 180 MPa (26.1 ksi). In exchange, LM25-TB7 is the more ductile: elongation 4% versus 3% for LM25-T6, and LM25-T6 is harder (95 HB vs 65 HB). LM25-TB7 runs hotter in service (200°C vs 150°C continuous).

LM25-T6Choose it when strength drives the design.

LM25-TB7Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

LM25-T6 vs LM25-TB7: properties

LM25-T6LM25-TB7

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

250 MPa36.3 ksi
180 MPa26.1 ksi

Yield Strength (0.2% offset)

215 MPa31.2 ksi
105 MPa15.2 ksi

Elongation at Break

3%
4%

Shear Strength

180 MPa26.1 ksi
135 MPa19.6 ksi

Fatigue Strength (Endurance Limit)

90 MPa13.1 ksi
70 MPa10.2 ksi

Hardness, Brinell

95 HB
65 HB

Same in both: Elastic (Young's) Modulus 71 GPa10.3 Msi · Shear Modulus 26.5 GPa3.8 Msi · Bulk Modulus 70 GPa10.2 Msi · Poisson's Ratio 0.33 · Fracture Toughness (K_IC) 22 MPa·√m20 ksi·√in · Charpy V-Notch Impact (RT) 4 J3 ft·lbf · Hardness, Vickers 100 HV

Physical

Density and transition temperatures.

Same in both: Density 2.68 g/cm³0.1 lb/in³ · Melting Point (Solidus) 555°C1,031 °F · Liquidus Temperature 615°C1,139 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

151 W/m·K87.2 BTU/hr·ft·°F
158 W/m·K91.3 BTU/hr·ft·°F

Max Service Temperature (continuous)

150°C302 °F
200°C392 °F

Same in both: Specific Heat Capacity 963 J/kg·K0.23 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 22 µm/m·K12.2 µin/in·°F · Latent Heat of Fusion 389 J/g167 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

39 % IACS
41 % IACS

Same in both: Electrical Resistivity 4.4×10⁻⁸ Ω·m1.73 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.83 V · Corrosion Resistance 65 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

65 / 100
58 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 70% · Weldability 75 / 100 · Formability (cold) 10 / 100 · Castability 95 / 100 · Brazeability / Solderability 35 / 100 · Polishability 45 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 190 MJ/kg81,685 BTU/lb · Embodied Carbon (primary production) 12 kg CO₂/kg · Embodied Water 1,200 L/kg144 gal/lb · Typical Recycled Content 50%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scaleLM25

LM25-T6 vs LM25-TB7 — frequently asked

Is LM25-T6 stronger than LM25-TB7?

Yes. LM25-T6 has a typical yield strength of 215 MPa (31.2 ksi) against 105 MPa (15.2 ksi) for LM25-TB7 — about 105% more. Tensile strength is 250 MPa (36.3 ksi) vs 180 MPa (26.1 ksi).

Which condition does FabDigit quote by default, T6 or TB7?

T6 is the default LM25 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, LM25-T6 or LM25-TB7?

LM25-T6, by a small margin. Both rate good for machinability — 65/100 against 58/100 for LM25-TB7.

Ready to make it?

Upload a CAD file and FabDigit prices the part in LM25-T6 and LM25-TB7 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.