FabDigitFabDigit

Aluminum ER4010-AW vs ER4010-T4

Aluminum · ER4010 temper comparison

ER4010-AW and ER4010-T4 are two conditions of the same aluminum grade, ER4010: AW (as-welded deposit) versus T4 (solution heat treated and naturally aged). The chemistry is identical, so every difference below comes from the condition. ER4010-T4 is the stronger of the two: yield strength 125 MPa (18.1 ksi) against 95 MPa (13.8 ksi) for ER4010-AW, about 32% more; tensile strength follows at 230 MPa (33.4 ksi) vs 180 MPa (26.1 ksi). ER4010-T4 is the more ductile: elongation 10% versus 5% for ER4010-AW, and ER4010-T4 is harder (60 HB vs 55 HB). ER4010-AW runs hotter in service (150°C vs 120°C continuous).

ER4010-AWChoose it when the part sees heat.

ER4010-T4Choose it when strength drives the design, or when the part is bent, formed or impact-loaded.

ER4010-AW vs ER4010-T4: properties

ER4010-AWER4010-T4

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

180 MPa26.1 ksi
230 MPa33.4 ksi

Yield Strength (0.2% offset)

95 MPa13.8 ksi
125 MPa18.1 ksi

Elongation at Break

5%
10%

Shear Strength

115 MPa16.7 ksi
145 MPa21 ksi

Fatigue Strength (Endurance Limit)

55 MPa8 ksi
65 MPa9.4 ksi

Fracture Toughness (K_IC)

20 MPa·√m18.2 ksi·√in
24 MPa·√m21.8 ksi·√in

Charpy V-Notch Impact (RT)

6 J4.4 ft·lbf
9 J6.6 ft·lbf

Hardness, Brinell

55 HB
60 HB

Same in both: Elastic (Young's) Modulus 72 GPa10.4 Msi · Shear Modulus 27 GPa3.9 Msi · Bulk Modulus 70 GPa10.2 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.67 g/cm³0.1 lb/in³ · Melting Point (Solidus) 557°C1,035 °F · Liquidus Temperature 613°C1,135 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

152 W/m·K87.8 BTU/hr·ft·°F
141 W/m·K81.5 BTU/hr·ft·°F

Max Service Temperature (continuous)

150°C302 °F
120°C248 °F

Same in both: Specific Heat Capacity 963 J/kg·K0.23 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 21.5 µm/m·K11.9 µin/in·°F · Latent Heat of Fusion 389 J/g167 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

39 % IACS
36 % IACS

Electrical Resistivity

4.4×10⁻⁸ Ω·m1.73 µΩ·in
4.79×10⁻⁸ Ω·m1.89 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.83 V · Corrosion Resistance 62 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

55 / 100
50 / 100

Machinability Rating (AISI 1212 = 100 %)

90%
85%

Formability (cold)

45 / 100
55 / 100

Same in both: Weldability 92 / 100 · Castability 90 / 100 · Brazeability / Solderability 30 / 100 · Polishability 45 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12.5 kg CO₂/kg · Embodied Water 1,150 L/kg138 gal/lb · Typical Recycled Content 20%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scaleER4010

ER4010-AW vs ER4010-T4 — frequently asked

Is ER4010-T4 stronger than ER4010-AW?

Yes. ER4010-T4 has a typical yield strength of 125 MPa (18.1 ksi) against 95 MPa (13.8 ksi) for ER4010-AW — about 32% more. Tensile strength is 230 MPa (33.4 ksi) vs 180 MPa (26.1 ksi).

Which condition does FabDigit quote by default, AW or T4?

AW is the default ER4010 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, ER4010-AW or ER4010-T4?

ER4010-AW. Its machinability rates good (55/100) against fair (50/100) for ER4010-T4.

Ready to make it?

Upload a CAD file and FabDigit prices the part in ER4010-AW and ER4010-T4 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.