FabDigitFabDigit

Aluminum ER4009-F vs ER4009-T6

Aluminum · ER4009 temper comparison

ER4009-F and ER4009-T6 are two conditions of the same aluminum grade, ER4009: F (as fabricated) versus T6 (solution heat treated and artificially aged). The chemistry is identical, so every difference below comes from the condition. ER4009-T6 is the stronger of the two: yield strength 215 MPa (31.2 ksi) against 150 MPa (21.8 ksi) for ER4009-F, about 43% more; tensile strength follows at 290 MPa (42.1 ksi) vs 215 MPa (31.2 ksi). In exchange, ER4009-F is the more ductile: elongation 6% versus 3% for ER4009-T6, and ER4009-T6 is harder (88 HB vs 65 HB). On the shop floor, ER4009-T6 machines more easily (68 vs 55 out of 100).

ER4009-FChoose it when the part is bent, formed or impact-loaded.

ER4009-T6Choose it when strength drives the design, or when the part is machined in volume.

ER4009-F vs ER4009-T6: properties

ER4009-FER4009-T6

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

215 MPa31.2 ksi
290 MPa42.1 ksi

Yield Strength (0.2% offset)

150 MPa21.8 ksi
215 MPa31.2 ksi

Elongation at Break

6%
3%

Shear Strength

140 MPa20.3 ksi
195 MPa28.3 ksi

Fatigue Strength (Endurance Limit)

65 MPa9.4 ksi
90 MPa13.1 ksi

Hardness, Brinell

65 HB
88 HB

Same in both: Elastic (Young's) Modulus 71 GPa10.3 Msi · Shear Modulus 26.5 GPa3.8 Msi · Bulk Modulus 71 GPa10.3 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.71 g/cm³0.1 lb/in³ · Melting Point (Solidus) 546°C1,015 °F · Liquidus Temperature 621°C1,150 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

148 W/m·K85.5 BTU/hr·ft·°F
150 W/m·K86.7 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 963 J/kg·K0.23 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 22.4 µm/m·K12.4 µin/in·°F · Latent Heat of Fusion 400 J/g172 BTU/lb · Max Service Temperature (continuous) 150°C302 °F · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

38 % IACS
39 % IACS

Electrical Resistivity

4.54×10⁻⁸ Ω·m1.79 µΩ·in
4.4×10⁻⁸ Ω·m1.73 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.78 V · Corrosion Resistance 45 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

55 / 100
68 / 100

Machinability Rating (AISI 1212 = 100 %)

120%
130%

Weldability

88 / 100
85 / 100

Formability (cold)

55 / 100
45 / 100

Same in both: Castability 88 / 100 · Brazeability / Solderability 30 / 100 · Polishability 50 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 158 MJ/kg67,928 BTU/lb · Embodied Carbon (primary production) 11.5 kg CO₂/kg · Embodied Water 1,150 L/kg138 gal/lb · Typical Recycled Content 10%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scaleER4009

ER4009-F vs ER4009-T6 — frequently asked

Is ER4009-T6 stronger than ER4009-F?

Yes. ER4009-T6 has a typical yield strength of 215 MPa (31.2 ksi) against 150 MPa (21.8 ksi) for ER4009-F — about 43% more. Tensile strength is 290 MPa (42.1 ksi) vs 215 MPa (31.2 ksi).

Which condition does FabDigit quote by default, F or T6?

AW is the default ER4009 condition in the FabDigit quote flow (neither F nor T6). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, ER4009-F or ER4009-T6?

ER4009-T6, by a small margin. Both rate good for machinability — 68/100 against 55/100 for ER4009-F.

Ready to make it?

Upload a CAD file and FabDigit prices the part in ER4009-F and ER4009-T6 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.