FabDigitFabDigit

Aluminum EN AC-71000-F vs EN AC-71000-T5

Aluminum · EN AC-71000 temper comparison

EN AC-71000-F and EN AC-71000-T5 are two conditions of the same aluminum grade, EN AC-71000: F (as fabricated) versus T5 (cooled from hot working and artificially aged). The chemistry is identical, so every difference below comes from the condition. EN AC-71000-T5 is the stronger of the two: yield strength 170 MPa (24.7 ksi) against 145 MPa (21 ksi) for EN AC-71000-F, about 17% more. In exchange, EN AC-71000-F is the more ductile: elongation 4% versus 2% for EN AC-71000-T5, and EN AC-71000-T5 is harder (80 HB vs 62 HB).

EN AC-71000-FChoose it when the part is bent, formed or impact-loaded.

EN AC-71000-T5Choose it when strength drives the design.

EN AC-71000-F vs EN AC-71000-T5: properties

EN AC-71000-FEN AC-71000-T5

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

215 MPa31.2 ksi
225 MPa32.6 ksi

Yield Strength (0.2% offset)

145 MPa21 ksi
170 MPa24.7 ksi

Elongation at Break

4%
2%

Compressive Strength

150 MPa21.8 ksi
175 MPa25.4 ksi

Shear Strength

155 MPa22.5 ksi
170 MPa24.7 ksi

Fatigue Strength (Endurance Limit)

62 MPa9 ksi
70 MPa10.2 ksi

Fracture Toughness (K_IC)

17 MPa·√m15.5 ksi·√in
15 MPa·√m13.7 ksi·√in

Charpy V-Notch Impact (RT)

4 J3 ft·lbf
3 J2.2 ft·lbf

Hardness, Brinell

62 HB
80 HB

Hardness, Vickers

70 HV
85 HV

Same in both: Elastic (Young's) Modulus 72 GPa10.4 Msi · Shear Modulus 27 GPa3.9 Msi · Bulk Modulus 71 GPa10.3 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.85 g/cm³0.1 lb/in³ · Melting Point (Solidus) 550°C1,022 °F · Liquidus Temperature 610°C1,130 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

125 W/m·K72.2 BTU/hr·ft·°F
132 W/m·K76.3 BTU/hr·ft·°F

Max Service Temperature (continuous)

150°C302 °F
160°C320 °F

Same in both: Specific Heat Capacity 880 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 22.5 µm/m·K12.5 µin/in·°F · Latent Heat of Fusion 390 J/g168 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

30 % IACS
32 % IACS

Electrical Resistivity

5.75×10⁻⁸ Ω·m2.26 µΩ·in
5.39×10⁻⁸ Ω·m2.12 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

45 / 100
50 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.95 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

72 / 100
75 / 100

Machinability Rating (AISI 1212 = 100 %)

70%
73%

Formability (cold)

10 / 100
7 / 100

Same in both: Weldability 40 / 100 · Castability 62 / 100 · Brazeability / Solderability 25 / 100 · Polishability 55 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 180 MJ/kg77,386 BTU/lb · Embodied Carbon (primary production) 11.5 kg CO₂/kg · Embodied Water 1,100 L/kg132 gal/lb · Typical Recycled Content 60%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scaleEN AC-71000

EN AC-71000-F vs EN AC-71000-T5 — frequently asked

Is EN AC-71000-T5 stronger than EN AC-71000-F?

Yes. EN AC-71000-T5 has a typical yield strength of 170 MPa (24.7 ksi) against 145 MPa (21 ksi) for EN AC-71000-F — about 17% more. Tensile strength is 225 MPa (32.6 ksi) vs 215 MPa (31.2 ksi).

Which condition does FabDigit quote by default, F or T5?

F is the default EN AC-71000 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose EN AC-71000-F over EN AC-71000-T5?

Pick EN AC-71000-F when the part is bent, formed or impact-loaded. Pick EN AC-71000-T5 when strength drives the design.

Ready to make it?

Upload a CAD file and FabDigit prices the part in EN AC-71000-F and EN AC-71000-T5 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.