FabDigitFabDigit

Aluminum EN AC-46600-T5 vs EN AC-46600 T6-S

Aluminum · EN AC-46600 temper comparison

EN AC-46600-T5 and EN AC-46600 T6-S are two conditions of the same aluminum grade, EN AC-46600: T5 (cooled from hot working and artificially aged) versus T6-S (T6). The chemistry is identical, so every difference below comes from the condition. EN AC-46600 T6-S is the stronger of the two: yield strength 200 MPa (29 ksi) against 170 MPa (24.7 ksi) for EN AC-46600-T5, about 18% more. EN AC-46600 T6-S is harder — 90 HB against 85 HB for EN AC-46600-T5 — which matters for wear surfaces and threads. EN AC-46600-T5 runs hotter in service (175°C vs 150°C continuous).

EN AC-46600-T5Choose it when the part sees heat.

EN AC-46600 T6-SChoose it when strength drives the design, or when surface hardness matters.

EN AC-46600-T5 vs EN AC-46600 T6-S: properties

EN AC-46600-T5EN AC-46600 T6-S

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

230 MPa33.4 ksi
240 MPa34.8 ksi

Yield Strength (0.2% offset)

170 MPa24.7 ksi
200 MPa29 ksi

Compressive Strength

280 MPa40.6 ksi
260 MPa37.7 ksi

Shear Strength

155 MPa22.5 ksi
160 MPa23.2 ksi

Fracture Toughness (K_IC)

15 MPa·√m13.7 ksi·√in
16 MPa·√m14.6 ksi·√in

Charpy V-Notch Impact (RT)

3 J1.8 ft·lbf
2 J1.5 ft·lbf

Hardness, Brinell

85 HB
90 HB

Same in both: Elastic (Young's) Modulus 75 GPa10.9 Msi · Shear Modulus 27 GPa3.9 Msi · Bulk Modulus 71 GPa10.3 Msi · Poisson's Ratio 0.33 · Elongation at Break 1% · Fatigue Strength (Endurance Limit) 85 MPa12.3 ksi

Physical

Density and transition temperatures.

Same in both: Density 2.75 g/cm³0.1 lb/in³ · Melting Point (Solidus) 525°C977 °F · Liquidus Temperature 610°C1,130 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

150 W/m·K86.7 BTU/hr·ft·°F
155 W/m·K89.6 BTU/hr·ft·°F

Max Service Temperature (continuous)

175°C347 °F
150°C302 °F

Same in both: Specific Heat Capacity 880 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 21.5 µm/m·K11.9 µin/in·°F · Latent Heat of Fusion 425 J/g183 BTU/lb · Min Service Temperature -60°C-76 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

33 % IACS
35 % IACS

Electrical Resistivity

5.2×10⁻⁸ Ω·m2.05 µΩ·in
4.9×10⁻⁸ Ω·m1.93 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

42 / 100
40 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.75 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

72 / 100
75 / 100

Machinability Rating (AISI 1212 = 100 %)

135%
140%

Weldability

30 / 100
25 / 100

Same in both: Castability 85 / 100 · Brazeability / Solderability 25 / 100 · Polishability 40 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 195 MJ/kg83,835 BTU/lb · Embodied Carbon (primary production) 11.5 kg CO₂/kg · Embodied Water 1,100 L/kg132 gal/lb · Typical Recycled Content 85%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scaleEN AC-46600

EN AC-46600-T5 vs EN AC-46600 T6-S — frequently asked

Is EN AC-46600 T6-S stronger than EN AC-46600-T5?

Yes. EN AC-46600 T6-S has a typical yield strength of 200 MPa (29 ksi) against 170 MPa (24.7 ksi) for EN AC-46600-T5 — about 18% more. Tensile strength is 240 MPa (34.8 ksi) vs 230 MPa (33.4 ksi).

Which condition does FabDigit quote by default, T5 or T6-S?

F-D is the default EN AC-46600 condition in the FabDigit quote flow (neither T5 nor T6-S). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which welds better, EN AC-46600-T5 or EN AC-46600 T6-S?

EN AC-46600-T5. Its weldability rates poor (30/100) against poor (25/100) for EN AC-46600 T6-S.

Ready to make it?

Upload a CAD file and FabDigit prices the part in EN AC-46600-T5 and EN AC-46600 T6-S side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.