Aluminum EN AC-46500 F-GDC vs EN AC-46500-T5
Aluminum · EN AC-46500 temper comparison
EN AC-46500 F-GDC and EN AC-46500-T5 are two conditions of the same aluminum grade, EN AC-46500: F-GDC (f) versus T5 (cooled from hot working and artificially aged). The chemistry is identical, so every difference below comes from the condition. EN AC-46500-T5 is the stronger of the two: yield strength 190 MPa (27.6 ksi) against 120 MPa (17.4 ksi) for EN AC-46500 F-GDC, about 58% more; tensile strength follows at 310 MPa (45 ksi) vs 190 MPa (27.6 ksi). EN AC-46500-T5 is harder — 95 HB against 75 HB for EN AC-46500 F-GDC — which matters for wear surfaces and threads. EN AC-46500-T5 runs hotter in service (170°C vs 150°C continuous).
EN AC-46500-T5Choose it when strength drives the design, or when surface hardness matters.
EN AC-46500 F-GDC vs EN AC-46500-T5: propertiesHow to read these bars
- One bar per material. A full bar is the highest value among all aluminum grades in the FabDigit library; each bar is drawn as a share of that.
- The better value (by the usual engineering direction) is in bold. Rows with no direction — density, thermal conductivity — have no bold.
- Values are typical room-temperature figures for the condition named on each card.
- Confirm against the certified mill or resin datasheet before design release.
How to read these bars
- One bar per material. A full bar is the highest value among all aluminum grades in the FabDigit library; each bar is drawn as a share of that.
- The better value (by the usual engineering direction) is in bold. Rows with no direction — density, thermal conductivity — have no bold.
- Values are typical room-temperature figures for the condition named on each card.
- Confirm against the certified mill or resin datasheet before design release.
EN AC-46500 F-GDCEN AC-46500-T5
Mechanical
Strength, stiffness, ductility and hardness at room temperature.
Elastic (Young's) Modulus
Tensile Strength (Ultimate)
Yield Strength (0.2% offset)
Shear Strength
Fatigue Strength (Endurance Limit)
Fracture Toughness (K_IC)
Charpy V-Notch Impact (RT)
Hardness, Brinell
Same in both: Shear Modulus 26.5 GPa3.8 Msi · Bulk Modulus 72 GPa10.4 Msi · Poisson's Ratio 0.33 · Elongation at Break 1%
Physical
Density and transition temperatures.
Same in both: Density 2.75 g/cm³0.1 lb/in³ · Melting Point (Solidus) 516°C961 °F · Liquidus Temperature 585°C1,085 °F
Thermal
How each material carries heat and how hot it can run.
Max Service Temperature (continuous)
Same in both: Thermal Conductivity 105 W/m·K60.7 BTU/hr·ft·°F · Specific Heat Capacity 963 J/kg·K0.23 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 21 µm/m·K11.7 µin/in·°F · Latent Heat of Fusion 389 J/g167 BTU/lb · Min Service Temperature -50°C-58 °F
Electrical
Conductivity and insulation.
Electrical Conductivity
Electrical Resistivity
Chemical & Environmental
Corrosion and environmental resistance (0–100 scores).
Corrosion Resistance
Same in both: Galvanic Potential (seawater, vs SCE) -0.78 V
Manufacturability
FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.
Machinability
Machinability Rating (AISI 1212 = 100 %)
Weldability
Same in both: Formability (cold) 6 / 100 · Castability 93 / 100 · Brazeability / Solderability 18 / 100 · Polishability 40 / 100
Sustainability
Primary-production footprint per kilogram.
Same in both: Embodied Energy (primary production) 155 MJ/kg66,638 BTU/lb · Embodied Carbon (primary production) 9.5 kg CO₂/kg · Embodied Water 1,100 L/kg132 gal/lb · Typical Recycled Content 92%
Strength versus weight
Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.
EN AC-46500 F-GDC vs EN AC-46500-T5 — frequently asked
Is EN AC-46500-T5 stronger than EN AC-46500 F-GDC?
Yes. EN AC-46500-T5 has a typical yield strength of 190 MPa (27.6 ksi) against 120 MPa (17.4 ksi) for EN AC-46500 F-GDC — about 58% more. Tensile strength is 310 MPa (45 ksi) vs 190 MPa (27.6 ksi).
Which condition does FabDigit quote by default, F-GDC or T5?
F is the default EN AC-46500 condition in the FabDigit quote flow (neither F-GDC nor T5). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.
When should I choose EN AC-46500 F-GDC over EN AC-46500-T5?
Pick EN AC-46500-T5 when strength drives the design, or when surface hardness matters.
Ready to make it?
Upload a CAD file and FabDigit prices the part in EN AC-46500 F-GDC and EN AC-46500-T5 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.
Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.