FabDigitFabDigit

Aluminum EN AC-46200-T5 vs EN AC-46200-T7

Aluminum · EN AC-46200 temper comparison

EN AC-46200-T5 and EN AC-46200-T7 are two conditions of the same aluminum grade, EN AC-46200: T5 (cooled from hot working and artificially aged) versus T7 (solution heat treated and overaged (stabilized)). The chemistry is identical, so every difference below comes from the condition. EN AC-46200-T5 is the stronger of the two: yield strength 175 MPa (25.4 ksi) against 155 MPa (22.5 ksi) for EN AC-46200-T7, about 13% more. In exchange, EN AC-46200-T7 is the more ductile: elongation 3% versus 1.5% for EN AC-46200-T5, and EN AC-46200-T5 is harder (85 HB vs 80 HB). EN AC-46200-T7 runs hotter in service (200°C vs 175°C continuous).

EN AC-46200-T5Choose it when strength drives the design.

EN AC-46200-T7Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

EN AC-46200-T5 vs EN AC-46200-T7: properties

EN AC-46200-T5EN AC-46200-T7

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

215 MPa31.2 ksi
230 MPa33.4 ksi

Yield Strength (0.2% offset)

175 MPa25.4 ksi
155 MPa22.5 ksi

Elongation at Break

1.5%
3%

Shear Strength

165 MPa23.9 ksi
175 MPa25.4 ksi

Fracture Toughness (K_IC)

17 MPa·√m15.5 ksi·√in
21 MPa·√m19.1 ksi·√in

Charpy V-Notch Impact (RT)

3 J2.2 ft·lbf
6 J4.4 ft·lbf

Hardness, Brinell

85 HB
80 HB

Hardness, Vickers

90 HV
85 HV

Same in both: Elastic (Young's) Modulus 75 GPa10.9 Msi · Shear Modulus 28 GPa4.1 Msi · Bulk Modulus 72 GPa10.4 Msi · Poisson's Ratio 0.33 · Fatigue Strength (Endurance Limit) 75 MPa10.9 ksi

Physical

Density and transition temperatures.

Same in both: Density 2.75 g/cm³0.1 lb/in³ · Melting Point (Solidus) 510°C950 °F · Liquidus Temperature 600°C1,112 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

115 W/m·K66.4 BTU/hr·ft·°F
125 W/m·K72.2 BTU/hr·ft·°F

Max Service Temperature (continuous)

175°C347 °F
200°C392 °F

Same in both: Specific Heat Capacity 963 J/kg·K0.23 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 21.5 µm/m·K11.9 µin/in·°F · Latent Heat of Fusion 389 J/g167 BTU/lb · Min Service Temperature -80°C-112 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

28 % IACS
30 % IACS

Electrical Resistivity

6.2×10⁻⁸ Ω·m2.44 µΩ·in
5.75×10⁻⁸ Ω·m2.26 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

42 / 100
45 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.75 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

78 / 100
76 / 100

Weldability

30 / 100
32 / 100

Formability (cold)

5 / 100
8 / 100

Same in both: Castability 88 / 100 · Brazeability / Solderability 20 / 100 · Polishability 40 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 190 MJ/kg81,685 BTU/lb · Embodied Carbon (primary production) 11.5 kg CO₂/kg · Embodied Water 1,100 L/kg132 gal/lb · Typical Recycled Content 80%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scaleEN AC-46200

EN AC-46200-T5 vs EN AC-46200-T7 — frequently asked

Is EN AC-46200-T5 stronger than EN AC-46200-T7?

Yes. EN AC-46200-T5 has a typical yield strength of 175 MPa (25.4 ksi) against 155 MPa (22.5 ksi) for EN AC-46200-T7 — about 13% more. Tensile strength is 215 MPa (31.2 ksi) vs 230 MPa (33.4 ksi).

Which condition does FabDigit quote by default, T5 or T7?

F-K is the default EN AC-46200 condition in the FabDigit quote flow (neither T5 nor T7). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose EN AC-46200-T5 over EN AC-46200-T7?

Pick EN AC-46200-T5 when strength drives the design. Pick EN AC-46200-T7 when the part is bent, formed or impact-loaded, or when the part sees heat.

Ready to make it?

Upload a CAD file and FabDigit prices the part in EN AC-46200-T5 and EN AC-46200-T7 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.