EN AC-46200 F-S and EN AC-46200-T6 are two conditions of the same aluminum grade, EN AC-46200: F-S (f) versus T6 (solution heat treated and artificially aged). The chemistry is identical, so every difference below comes from the condition. EN AC-46200-T6 is the stronger of the two: yield strength 185 MPa (26.8 ksi) against 105 MPa (15.2 ksi) for EN AC-46200 F-S, about 76% more; tensile strength follows at 270 MPa (39.2 ksi) vs 175 MPa (25.4 ksi). EN AC-46200-T6 is the more ductile: elongation 2.5% versus 1.5% for EN AC-46200 F-S, and EN AC-46200-T6 is harder (95 HB vs 70 HB).

EN AC-46200-T6Choose it when strength drives the design, or when the part is bent, formed or impact-loaded.

EN AC-46200 F-S vs EN AC-46200-T6: properties

EN AC-46200 F-SEN AC-46200-T6

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Elastic (Young's) Modulus

74 GPa10.7 Msi
75 GPa10.9 Msi

Tensile Strength (Ultimate)

175 MPa25.4 ksi
270 MPa39.2 ksi

Yield Strength (0.2% offset)

105 MPa15.2 ksi
185 MPa26.8 ksi

Elongation at Break

1.5%
2.5%

Shear Strength

140 MPa20.3 ksi
200 MPa29 ksi

Fatigue Strength (Endurance Limit)

65 MPa9.4 ksi
80 MPa11.6 ksi

Fracture Toughness (K_IC)

17 MPa·√m15.5 ksi·√in
18 MPa·√m16.4 ksi·√in

Charpy V-Notch Impact (RT)

3 J2.2 ft·lbf
4 J3 ft·lbf

Hardness, Brinell

70 HB
95 HB

Hardness, Vickers

75 HV
85 HV

Same in both: Shear Modulus 28 GPa4.1 Msi · Bulk Modulus 72 GPa10.4 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.75 g/cm³0.1 lb/in³ · Melting Point (Solidus) 510°C950 °F · Liquidus Temperature 600°C1,112 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

108 W/m·K62.4 BTU/hr·ft·°F
118 W/m·K68.2 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 963 J/kg·K0.23 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 21.5 µm/m·K11.9 µin/in·°F · Latent Heat of Fusion 389 J/g167 BTU/lb · Max Service Temperature (continuous) 150°C302 °F · Min Service Temperature -80°C-112 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

27 % IACS
29 % IACS

Same in both: Electrical Resistivity 6.4×10⁻⁸ Ω·m2.52 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.75 V · Corrosion Resistance 42 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

75 / 100
80 / 100

Same in both: Weldability 30 / 100 · Formability (cold) 5 / 100 · Castability 88 / 100 · Brazeability / Solderability 20 / 100 · Polishability 40 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 190 MJ/kg81,685 BTU/lb · Embodied Carbon (primary production) 11.5 kg CO₂/kg · Embodied Water 1,100 L/kg132 gal/lb · Typical Recycled Content 80%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scaleEN AC-46200

EN AC-46200 F-S vs EN AC-46200-T6 — frequently asked

Is EN AC-46200-T6 stronger than EN AC-46200 F-S?

Yes. EN AC-46200-T6 has a typical yield strength of 185 MPa (26.8 ksi) against 105 MPa (15.2 ksi) for EN AC-46200 F-S — about 76% more. Tensile strength is 270 MPa (39.2 ksi) vs 175 MPa (25.4 ksi).

Which condition does FabDigit quote by default, F-S or T6?

F-K is the default EN AC-46200 condition in the FabDigit quote flow (neither F-S nor T6). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, EN AC-46200 F-S or EN AC-46200-T6?

EN AC-46200-T6, by a small margin. Both rate very good for machinability — 80/100 against 75/100 for EN AC-46200 F-S.

Ready to make it?

Upload a CAD file and FabDigit prices the part in EN AC-46200 F-S and EN AC-46200-T6 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.