FabDigitFabDigit

Aluminum EN AC-45400-F vs EN AC-45400-T5

Aluminum · EN AC-45400 temper comparison

EN AC-45400-F and EN AC-45400-T5 are two conditions of the same aluminum grade, EN AC-45400: F (as fabricated) versus T5 (cooled from hot working and artificially aged). The chemistry is identical, so every difference below comes from the condition. EN AC-45400-T5 is the stronger of the two: yield strength 145 MPa (21 ksi) against 95 MPa (13.8 ksi) for EN AC-45400-F, about 53% more; tensile strength follows at 205 MPa (29.7 ksi) vs 165 MPa (23.9 ksi). EN AC-45400-T5 is the more ductile: elongation 2% versus 1.5% for EN AC-45400-F, and EN AC-45400-T5 is harder (85 HB vs 70 HB).

EN AC-45400-T5Choose it when strength drives the design, or when the part is bent, formed or impact-loaded.

EN AC-45400-F vs EN AC-45400-T5: properties

EN AC-45400-FEN AC-45400-T5

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

165 MPa23.9 ksi
205 MPa29.7 ksi

Yield Strength (0.2% offset)

95 MPa13.8 ksi
145 MPa21 ksi

Elongation at Break

1.5%
2%

Shear Strength

115 MPa16.7 ksi
145 MPa21 ksi

Fatigue Strength (Endurance Limit)

60 MPa8.7 ksi
70 MPa10.2 ksi

Fracture Toughness (K_IC)

16 MPa·√m14.6 ksi·√in
18 MPa·√m16.4 ksi·√in

Charpy V-Notch Impact (RT)

3 J2.2 ft·lbf
4 J3 ft·lbf

Hardness, Brinell

70 HB
85 HB

Same in both: Elastic (Young's) Modulus 75 GPa10.9 Msi · Shear Modulus 28 GPa4.1 Msi · Bulk Modulus 74 GPa10.7 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.75 g/cm³0.1 lb/in³ · Melting Point (Solidus) 525°C977 °F · Liquidus Temperature 625°C1,157 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

130 W/m·K75.1 BTU/hr·ft·°F
125 W/m·K72.2 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 900 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 21.5 µm/m·K11.9 µin/in·°F · Latent Heat of Fusion 390 J/g168 BTU/lb · Max Service Temperature (continuous) 175°C347 °F · Min Service Temperature -50°C-58 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

31 % IACS
30 % IACS

Electrical Resistivity

5.6×10⁻⁸ Ω·m2.2 µΩ·in
5.75×10⁻⁸ Ω·m2.26 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

38 / 100
37 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.78 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

72 / 100
70 / 100

Machinability Rating (AISI 1212 = 100 %)

75%
72%

Weldability

30 / 100
28 / 100

Same in both: Formability (cold) 3 / 100 · Castability 80 / 100 · Brazeability / Solderability 20 / 100 · Polishability 40 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 150 MJ/kg64,488 BTU/lb · Embodied Carbon (primary production) 10 kg CO₂/kg · Embodied Water 1,100 L/kg132 gal/lb · Typical Recycled Content 80%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scaleEN AC-45400

EN AC-45400-F vs EN AC-45400-T5 — frequently asked

Is EN AC-45400-T5 stronger than EN AC-45400-F?

Yes. EN AC-45400-T5 has a typical yield strength of 145 MPa (21 ksi) against 95 MPa (13.8 ksi) for EN AC-45400-F — about 53% more. Tensile strength is 205 MPa (29.7 ksi) vs 165 MPa (23.9 ksi).

Which condition does FabDigit quote by default, F or T5?

T4 is the default EN AC-45400 condition in the FabDigit quote flow (neither F nor T5). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose EN AC-45400-F over EN AC-45400-T5?

Pick EN AC-45400-T5 when strength drives the design, or when the part is bent, formed or impact-loaded.

Ready to make it?

Upload a CAD file and FabDigit prices the part in EN AC-45400-F and EN AC-45400-T5 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.