EN AC-45000-T5 and EN AC-45000-T7 are two conditions of the same aluminum grade, EN AC-45000: T5 (cooled from hot working and artificially aged) versus T7 (solution heat treated and overaged (stabilized)). The chemistry is identical, so every difference below comes from the condition. EN AC-45000-T7 is the stronger of the two: yield strength 150 MPa (21.8 ksi) against 140 MPa (20.3 ksi) for EN AC-45000-T5, about 7% more. EN AC-45000-T7 is the more ductile: elongation 2.5% versus 1.5% for EN AC-45000-T5. EN AC-45000-T7 runs hotter in service (230°C vs 200°C continuous).

EN AC-45000-T7Choose it when strength drives the design, or when the part is bent, formed or impact-loaded.

EN AC-45000-T5 vs EN AC-45000-T7: properties

EN AC-45000-T5EN AC-45000-T7

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

205 MPa29.7 ksi
215 MPa31.2 ksi

Yield Strength (0.2% offset)

140 MPa20.3 ksi
150 MPa21.8 ksi

Elongation at Break

1.5%
2.5%

Compressive Strength

110 MPa16 ksi
165 MPa23.9 ksi

Fatigue Strength (Endurance Limit)

75 MPa10.9 ksi
70 MPa10.2 ksi

Fracture Toughness (K_IC)

17 MPa·√m15.5 ksi·√in
19 MPa·√m17.3 ksi·√in

Charpy V-Notch Impact (RT)

4 J3 ft·lbf
5 J3.7 ft·lbf

Same in both: Elastic (Young's) Modulus 74 GPa10.7 Msi · Shear Modulus 28 GPa4.1 Msi · Bulk Modulus 71 GPa10.3 Msi · Poisson's Ratio 0.33 · Shear Strength 165 MPa23.9 ksi · Hardness, Brinell 80 HB

Physical

Density and transition temperatures.

Same in both: Density 2.77 g/cm³0.1 lb/in³ · Melting Point (Solidus) 520°C968 °F · Liquidus Temperature 605°C1,121 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

113 W/m·K65.3 BTU/hr·ft·°F
112 W/m·K64.7 BTU/hr·ft·°F

Max Service Temperature (continuous)

200°C392 °F
230°C446 °F

Same in both: Specific Heat Capacity 963 J/kg·K0.23 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 21.5 µm/m·K11.9 µin/in·°F · Latent Heat of Fusion 389 J/g167 BTU/lb · Min Service Temperature -50°C-58 °F

Electrical

Conductivity and insulation.

Electrical Resistivity

6.4×10⁻⁸ Ω·m2.52 µΩ·in
6.16×10⁻⁸ Ω·m2.43 µΩ·in

Same in both: Electrical Conductivity 28 % IACS

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

35 / 100
36 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.78 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Same in both: Machinability 72 / 100 · Weldability 25 / 100 · Castability 85 / 100 · Brazeability / Solderability 20 / 100 · Polishability 40 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 190 MJ/kg81,685 BTU/lb · Embodied Carbon (primary production) 12 kg CO₂/kg · Embodied Water 1,100 L/kg132 gal/lb · Typical Recycled Content 85%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scaleEN AC-45000

EN AC-45000-T5 vs EN AC-45000-T7 — frequently asked

Is EN AC-45000-T7 stronger than EN AC-45000-T5?

Yes. EN AC-45000-T7 has a typical yield strength of 150 MPa (21.8 ksi) against 140 MPa (20.3 ksi) for EN AC-45000-T5 — about 7% more. Tensile strength is 215 MPa (31.2 ksi) vs 205 MPa (29.7 ksi).

Which condition does FabDigit quote by default, T5 or T7?

F is the default EN AC-45000 condition in the FabDigit quote flow (neither T5 nor T7). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose EN AC-45000-T5 over EN AC-45000-T7?

Pick EN AC-45000-T7 when strength drives the design, or when the part is bent, formed or impact-loaded.

Ready to make it?

Upload a CAD file and FabDigit prices the part in EN AC-45000-T5 and EN AC-45000-T7 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.