FabDigitFabDigit

Aluminum EN AC-45000-F vs EN AC-45000-T6

Aluminum · EN AC-45000 temper comparison

EN AC-45000-F and EN AC-45000-T6 are two conditions of the same aluminum grade, EN AC-45000: F (as fabricated) versus T6 (solution heat treated and artificially aged). The chemistry is identical, so every difference below comes from the condition. EN AC-45000-T6 is the stronger of the two: yield strength 175 MPa (25.4 ksi) against 100 MPa (14.5 ksi) for EN AC-45000-F, about 75% more; tensile strength follows at 250 MPa (36.3 ksi) vs 170 MPa (24.7 ksi). EN AC-45000-T6 is the more ductile: elongation 2% versus 1.5% for EN AC-45000-F, and EN AC-45000-T6 is harder (90 HB vs 70 HB). EN AC-45000-T6 runs hotter in service (175°C vs 150°C continuous).

EN AC-45000-T6Choose it when strength drives the design, or when the part is bent, formed or impact-loaded.

EN AC-45000-F vs EN AC-45000-T6: properties

EN AC-45000-FEN AC-45000-T6

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

170 MPa24.7 ksi
250 MPa36.3 ksi

Yield Strength (0.2% offset)

100 MPa14.5 ksi
175 MPa25.4 ksi

Elongation at Break

1.5%
2%

Shear Strength

130 MPa18.9 ksi
200 MPa29 ksi

Fatigue Strength (Endurance Limit)

69 MPa10 ksi
75 MPa10.9 ksi

Hardness, Brinell

70 HB
90 HB

Same in both: Elastic (Young's) Modulus 74 GPa10.7 Msi · Shear Modulus 28 GPa4.1 Msi · Bulk Modulus 71 GPa10.3 Msi · Poisson's Ratio 0.33 · Compressive Strength 110 MPa16 ksi · Fracture Toughness (K_IC) 17 MPa·√m15.5 ksi·√in · Charpy V-Notch Impact (RT) 4 J3 ft·lbf

Physical

Density and transition temperatures.

Same in both: Density 2.77 g/cm³0.1 lb/in³ · Melting Point (Solidus) 520°C968 °F · Liquidus Temperature 605°C1,121 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

109 W/m·K63 BTU/hr·ft·°F
105 W/m·K60.7 BTU/hr·ft·°F

Max Service Temperature (continuous)

150°C302 °F
175°C347 °F

Same in both: Specific Heat Capacity 963 J/kg·K0.23 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 21.5 µm/m·K11.9 µin/in·°F · Latent Heat of Fusion 389 J/g167 BTU/lb · Min Service Temperature -50°C-58 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

27 % IACS
26 % IACS

Same in both: Electrical Resistivity 6.4×10⁻⁸ Ω·m2.52 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

35 / 100
32 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.78 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

70 / 100
75 / 100

Same in both: Weldability 25 / 100 · Castability 85 / 100 · Brazeability / Solderability 20 / 100 · Polishability 40 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 190 MJ/kg81,685 BTU/lb · Embodied Carbon (primary production) 12 kg CO₂/kg · Embodied Water 1,100 L/kg132 gal/lb · Typical Recycled Content 85%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scaleEN AC-45000

EN AC-45000-F vs EN AC-45000-T6 — frequently asked

Is EN AC-45000-T6 stronger than EN AC-45000-F?

Yes. EN AC-45000-T6 has a typical yield strength of 175 MPa (25.4 ksi) against 100 MPa (14.5 ksi) for EN AC-45000-F — about 75% more. Tensile strength is 250 MPa (36.3 ksi) vs 170 MPa (24.7 ksi).

Which condition does FabDigit quote by default, F or T6?

F is the default EN AC-45000 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, EN AC-45000-F or EN AC-45000-T6?

EN AC-45000-T6, by a small margin. Both rate very good for machinability — 75/100 against 70/100 for EN AC-45000-F.

Ready to make it?

Upload a CAD file and FabDigit prices the part in EN AC-45000-F and EN AC-45000-T6 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.