FabDigitFabDigit

Aluminum AC4D-F vs AC4D-T7

Aluminum · AC4D temper comparison

AC4D-F and AC4D-T7 are two conditions of the same aluminum grade, AC4D: F (as fabricated) versus T7 (solution heat treated and overaged (stabilized)). The chemistry is identical, so every difference below comes from the condition. AC4D-T7 is the stronger of the two: yield strength 235 MPa (34.1 ksi) against 100 MPa (14.5 ksi) for AC4D-F, about 135% more; tensile strength follows at 260 MPa (37.7 ksi) vs 170 MPa (24.7 ksi). In exchange, AC4D-F is the more ductile: elongation 2.5% versus 1% for AC4D-T7, and AC4D-T7 is harder (85 HB vs 65 HB). AC4D-T7 runs hotter in service (200°C vs 150°C continuous).

AC4D-FChoose it when the part is bent, formed or impact-loaded.

AC4D-T7Choose it when strength drives the design, or when the part sees heat.

AC4D-F vs AC4D-T7: properties

AC4D-FAC4D-T7

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

170 MPa24.7 ksi
260 MPa37.7 ksi

Yield Strength (0.2% offset)

100 MPa14.5 ksi
235 MPa34.1 ksi

Elongation at Break

2.5%
1%

Shear Strength

135 MPa19.6 ksi
195 MPa28.3 ksi

Fatigue Strength (Endurance Limit)

55 MPa8 ksi
62 MPa9 ksi

Hardness, Brinell

65 HB
85 HB

Same in both: Elastic (Young's) Modulus 71 GPa10.3 Msi · Shear Modulus 26.5 GPa3.8 Msi · Bulk Modulus 72 GPa10.4 Msi · Poisson's Ratio 0.33 · Fracture Toughness (K_IC) 20 MPa·√m18.2 ksi·√in · Charpy V-Notch Impact (RT) 4 J3 ft·lbf

Physical

Density and transition temperatures.

Same in both: Density 2.71 g/cm³0.1 lb/in³ · Melting Point (Solidus) 549°C1,020 °F · Liquidus Temperature 621°C1,150 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

165 W/m·K95.3 BTU/hr·ft·°F
158 W/m·K91.3 BTU/hr·ft·°F

Max Service Temperature (continuous)

150°C302 °F
200°C392 °F

Same in both: Specific Heat Capacity 963 J/kg·K0.23 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 22.3 µm/m·K12.4 µin/in·°F · Latent Heat of Fusion 425 J/g183 BTU/lb · Min Service Temperature -50°C-58 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

43 % IACS
41 % IACS

Same in both: Electrical Resistivity 4.42×10⁻⁸ Ω·m1.74 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.78 V · Corrosion Resistance 45 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

55 / 100
62 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 180% · Weldability 40 / 100 · Formability (cold) 10 / 100 · Castability 78 / 100 · Brazeability / Solderability 25 / 100 · Polishability 45 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12 kg CO₂/kg · Embodied Water 1,200 L/kg144 gal/lb · Typical Recycled Content 70%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scaleAC4D

AC4D-F vs AC4D-T7 — frequently asked

Is AC4D-T7 stronger than AC4D-F?

Yes. AC4D-T7 has a typical yield strength of 235 MPa (34.1 ksi) against 100 MPa (14.5 ksi) for AC4D-F — about 135% more. Tensile strength is 260 MPa (37.7 ksi) vs 170 MPa (24.7 ksi).

Which condition does FabDigit quote by default, F or T7?

T6 is the default AC4D condition in the FabDigit quote flow (neither F nor T7). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, AC4D-F or AC4D-T7?

AC4D-T7, by a small margin. Both rate good for machinability — 62/100 against 55/100 for AC4D-F.

Ready to make it?

Upload a CAD file and FabDigit prices the part in AC4D-F and AC4D-T7 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.