FabDigitFabDigit

Aluminum A206.0-T4 vs A206.0-T7

Aluminum · A206.0 temper comparison

A206.0-T4 and A206.0-T7 are two conditions of the same aluminum grade, A206.0: T4 (solution heat treated and naturally aged) versus T7 (solution heat treated and overaged (stabilized)). The chemistry is identical, so every difference below comes from the condition. A206.0-T7 is the stronger of the two: yield strength 345 MPa (50 ksi) against 264 MPa (38.3 ksi) for A206.0-T4, about 31% more. In exchange, A206.0-T4 is the more ductile: elongation 17% versus 11.7% for A206.0-T7, and A206.0-T7 is harder (115 HB vs 95 HB). A206.0-T7 runs hotter in service (200°C vs 150°C continuous) and A206.0-T7 conducts heat better (138 W/m·K vs 121 W/m·K).

A206.0-T4Choose it when the part is bent, formed or impact-loaded.

A206.0-T7Choose it when strength drives the design, or when the part sees heat.

A206.0-T4 vs A206.0-T7: properties

A206.0-T4A206.0-T7

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

430 MPa62.4 ksi
435 MPa63.1 ksi

Yield Strength (0.2% offset)

264 MPa38.3 ksi
345 MPa50 ksi

Elongation at Break

17%
11.7%

Shear Strength

260 MPa37.7 ksi
275 MPa39.9 ksi

Fatigue Strength (Endurance Limit)

105 MPa15.2 ksi
120 MPa17.4 ksi

Fracture Toughness (K_IC)

36 MPa·√m32.8 ksi·√in
28 MPa·√m25.5 ksi·√in

Hardness, Brinell

95 HB
115 HB

Hardness, Vickers

100 HV
122 HV

Same in both: Elastic (Young's) Modulus 71 GPa10.3 Msi · Shear Modulus 26.5 GPa3.8 Msi · Bulk Modulus 70 GPa10.2 Msi · Poisson's Ratio 0.33 · Compressive Strength 270 MPa39.2 ksi

Physical

Density and transition temperatures.

Same in both: Density 2.8 g/cm³0.1 lb/in³ · Melting Point (Solidus) 570°C1,058 °F · Liquidus Temperature 650°C1,202 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

121 W/m·K69.9 BTU/hr·ft·°F
138 W/m·K79.7 BTU/hr·ft·°F

Max Service Temperature (continuous)

150°C302 °F
200°C392 °F

Same in both: Specific Heat Capacity 921 J/kg·K0.22 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 22.5 µm/m·K12.5 µin/in·°F · Latent Heat of Fusion 390 J/g168 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

33 % IACS
39 % IACS

Electrical Resistivity

5.2×10⁻⁸ Ω·m2.05 µΩ·in
4.4×10⁻⁸ Ω·m1.73 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

30 / 100
36 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.72 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

78 / 100
80 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 70% · Weldability 30 / 100 · Formability (cold) 10 / 100 · Castability 28 / 100 · Brazeability / Solderability 15 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12.5 kg CO₂/kg · Embodied Water 1,200 L/kg144 gal/lb · Typical Recycled Content 15%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scaleA206.0

A206.0-T4 vs A206.0-T7 — frequently asked

Is A206.0-T7 stronger than A206.0-T4?

Yes. A206.0-T7 has a typical yield strength of 345 MPa (50 ksi) against 264 MPa (38.3 ksi) for A206.0-T4 — about 31% more. Tensile strength is 435 MPa (63.1 ksi) vs 430 MPa (62.4 ksi).

Which condition does FabDigit quote by default, T4 or T7?

T4 is the default A206.0 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose A206.0-T4 over A206.0-T7?

Pick A206.0-T4 when the part is bent, formed or impact-loaded. Pick A206.0-T7 when strength drives the design, or when the part sees heat.

Ready to make it?

Upload a CAD file and FabDigit prices the part in A206.0-T4 and A206.0-T7 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.