FabDigitFabDigit

Aluminum 8281-H16 vs 8281-H22

Aluminum · 8281 temper comparison

8281-H16 and 8281-H22 are two conditions of the same aluminum grade, 8281: H16 (strain hardened, three-quarter hard) versus H22 (strain hardened and partially annealed, quarter hard). The chemistry is identical, so every difference below comes from the condition. 8281-H16 is the stronger of the two: yield strength 130 MPa (18.9 ksi) against 90 MPa (13.1 ksi) for 8281-H22, about 44% more; tensile strength follows at 150 MPa (21.8 ksi) vs 115 MPa (16.7 ksi). In exchange, 8281-H22 is the more ductile: elongation 9% versus 4% for 8281-H16, and 8281-H16 is harder (42 HB vs 32 HB). 8281-H22 runs hotter in service (115°C vs 105°C continuous).

8281-H16Choose it when strength drives the design.

8281-H22Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

8281-H16 vs 8281-H22: properties

8281-H168281-H22

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

150 MPa21.8 ksi
115 MPa16.7 ksi

Yield Strength (0.2% offset)

130 MPa18.9 ksi
90 MPa13.1 ksi

Elongation at Break

4%
9%

Shear Strength

90 MPa13.1 ksi
72 MPa10.4 ksi

Fatigue Strength (Endurance Limit)

48 MPa7 ksi
42 MPa6.1 ksi

Hardness, Brinell

42 HB
32 HB

Same in both: Elastic (Young's) Modulus 69 GPa10 Msi · Shear Modulus 26 GPa3.8 Msi · Bulk Modulus 70 GPa10.2 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.71 g/cm³0.1 lb/in³ · Melting Point (Solidus) 645°C1,193 °F · Liquidus Temperature 655°C1,211 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

211 W/m·K122 BTU/hr·ft·°F
213 W/m·K123 BTU/hr·ft·°F

Max Service Temperature (continuous)

105°C221 °F
115°C239 °F

Same in both: Specific Heat Capacity 900 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.6 µm/m·K13.1 µin/in·°F · Latent Heat of Fusion 395 J/g170 BTU/lb · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

55 % IACS
55.5 % IACS

Electrical Resistivity

3.13×10⁻⁸ Ω·m1.23 µΩ·in
3.11×10⁻⁸ Ω·m1.22 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.8 V · Corrosion Resistance 58 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

38 / 100
33 / 100

Formability (cold)

45 / 100
72 / 100

Same in both: Weldability 70 / 100 · Brazeability / Solderability 65 / 100 · Polishability 50 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12 kg CO₂/kg · Embodied Water 1,200 L/kg144 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale8281

8281-H16 vs 8281-H22 — frequently asked

Is 8281-H16 stronger than 8281-H22?

Yes. 8281-H16 has a typical yield strength of 130 MPa (18.9 ksi) against 90 MPa (13.1 ksi) for 8281-H22 — about 44% more. Tensile strength is 150 MPa (21.8 ksi) vs 115 MPa (16.7 ksi).

Which condition does FabDigit quote by default, H16 or H22?

Specify the condition in the material field or the drawing note; FabDigit prices the quote for the state you call out.

Which is easier to machine, 8281-H16 or 8281-H22?

8281-H16. Its machinability rates fair (38/100) against poor (33/100) for 8281-H22.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 8281-H16 and 8281-H22 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.