FabDigitFabDigit

Aluminum 8017-H22 vs 8017-H26

Aluminum · 8017 temper comparison

8017-H22 and 8017-H26 are two conditions of the same aluminum grade, 8017: H22 (strain hardened and partially annealed, quarter hard) versus H26 (strain hardened and partially annealed, three-quarter hard). The chemistry is identical, so every difference below comes from the condition. 8017-H26 is the stronger of the two: yield strength 120 MPa (17.4 ksi) against 85 MPa (12.3 ksi) for 8017-H22, about 41% more; tensile strength follows at 140 MPa (20.3 ksi) vs 110 MPa (16 ksi). In exchange, 8017-H22 is the more ductile: elongation 17% versus 8% for 8017-H26, and 8017-H26 is harder (40 HB vs 30 HB). 8017-H22 runs hotter in service (140°C vs 120°C continuous).

8017-H22Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

8017-H26Choose it when strength drives the design.

8017-H22 vs 8017-H26: properties

8017-H228017-H26

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

110 MPa16 ksi
140 MPa20.3 ksi

Yield Strength (0.2% offset)

85 MPa12.3 ksi
120 MPa17.4 ksi

Elongation at Break

17%
8%

Shear Strength

70 MPa10.2 ksi
86 MPa12.5 ksi

Fatigue Strength (Endurance Limit)

43 MPa6.2 ksi
52 MPa7.5 ksi

Hardness, Brinell

30 HB
40 HB

Same in both: Elastic (Young's) Modulus 69 GPa10 Msi · Shear Modulus 26 GPa3.8 Msi · Bulk Modulus 75 GPa10.9 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.71 g/cm³0.1 lb/in³ · Melting Point (Solidus) 645°C1,193 °F · Liquidus Temperature 657°C1,215 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

232 W/m·K134 BTU/hr·ft·°F
230 W/m·K133 BTU/hr·ft·°F

Max Service Temperature (continuous)

140°C284 °F
120°C248 °F

Same in both: Specific Heat Capacity 900 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.6 µm/m·K13.1 µin/in·°F · Latent Heat of Fusion 397 J/g171 BTU/lb · Min Service Temperature -200°C-328 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

61.2 % IACS
60.8 % IACS

Electrical Resistivity

2.82×10⁻⁸ Ω·m1.11 µΩ·in
2.84×10⁻⁸ Ω·m1.12 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.84 V · Corrosion Resistance 58 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

28 / 100
33 / 100

Machinability Rating (AISI 1212 = 100 %)

28%
33%

Weldability

85 / 100
84 / 100

Formability (cold)

93 / 100
78 / 100

Same in both: Castability 45 / 100 · Brazeability / Solderability 55 / 100 · Polishability 50 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12 kg CO₂/kg · Embodied Water 1,100 L/kg132 gal/lb · Typical Recycled Content 20%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale8017

8017-H22 vs 8017-H26 — frequently asked

Is 8017-H26 stronger than 8017-H22?

Yes. 8017-H26 has a typical yield strength of 120 MPa (17.4 ksi) against 85 MPa (12.3 ksi) for 8017-H22 — about 41% more. Tensile strength is 140 MPa (20.3 ksi) vs 110 MPa (16 ksi).

Which condition does FabDigit quote by default, H22 or H26?

H12 is the default 8017 condition in the FabDigit quote flow (neither H22 nor H26). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 8017-H22 or 8017-H26?

8017-H26, by a small margin. Both rate poor for machinability — 33/100 against 28/100 for 8017-H22.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 8017-H22 and 8017-H26 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.