771.0-F and 771.0-T6 are two conditions of the same aluminum grade, 771.0: F (as fabricated) versus T6 (solution heat treated and artificially aged). The chemistry is identical, so every difference below comes from the condition. 771.0-T6 is the stronger of the two: yield strength 241 MPa (35 ksi) against 125 MPa (18.1 ksi) for 771.0-F, about 93% more; tensile strength follows at 290 MPa (42.1 ksi) vs 200 MPa (29 ksi). 771.0-T6 is the more ductile: elongation 5% versus 3% for 771.0-F, and 771.0-T6 is harder (75 HB vs 60 HB). 771.0-T6 runs hotter in service (120°C vs 100°C continuous). On the shop floor, 771.0-T6 machines more easily (very good vs good).

771.0-T6Choose it when strength drives the design, or when the part is bent, formed or impact-loaded.

771.0-F vs 771.0-T6: properties

771.0-F771.0-T6

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

200 MPa29 ksi
290 MPa42.1 ksi

Yield Strength (0.2% offset)

125 MPa18.1 ksi
241 MPa35 ksi

Elongation at Break

3%
5%

Shear Strength

130 MPa18.9 ksi
190 MPa27.6 ksi

Fatigue Strength (Endurance Limit)

50 MPa7.3 ksi
72 MPa10.4 ksi

Hardness, Brinell

60 HB
75 HB

Same in both: Elastic (Young's) Modulus 71 GPa10.3 Msi · Shear Modulus 26.5 GPa3.8 Msi · Bulk Modulus 70 GPa10.2 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.81 g/cm³0.1 lb/in³ · Melting Point (Solidus) 604°C1,119 °F · Liquidus Temperature 643°C1,189 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

119 W/m·K68.8 BTU/hr·ft·°F
130 W/m·K75.1 BTU/hr·ft·°F

Max Service Temperature (continuous)

100°C212 °F
120°C248 °F

Same in both: Specific Heat Capacity 960 J/kg·K0.23 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 24 µm/m·K13.3 µin/in·°F · Latent Heat of Fusion 390 J/g168 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Resistivity

5.4×10⁻⁸ Ω·m2.13 µΩ·in
4.9×10⁻⁸ Ω·m1.93 µΩ·in

Same in both: Electrical Conductivity 32 % IACS

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.87 V · Corrosion Resistance 45 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

65 / 100
80 / 100

Machinability Rating (AISI 1212 = 100 %)

180%
300%

Formability (cold)

15 / 100
10 / 100

Same in both: Weldability 45 / 100 · Castability 45 / 100 · Brazeability / Solderability 20 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12.5 kg CO₂/kg · Embodied Water 1,200 L/kg144 gal/lb · Typical Recycled Content 25%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale771.0

771.0-F vs 771.0-T6 — frequently asked

Is 771.0-T6 stronger than 771.0-F?

Yes. 771.0-T6 has a typical yield strength of 241 MPa (35 ksi) against 125 MPa (18.1 ksi) for 771.0-F — about 93% more. Tensile strength is 290 MPa (42.1 ksi) vs 200 MPa (29 ksi).

Which condition does FabDigit quote by default, F or T6?

T71 is the default 771.0 condition in the FabDigit quote flow (neither F nor T6). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 771.0-F or 771.0-T6?

771.0-T6. Its machinability rates very good (80/100) against good (65/100) for 771.0-F.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 771.0-F and 771.0-T6 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.