7449-O and 7449 T76511 are two conditions of the same aluminum grade, 7449: O (annealed) versus T76511 (extrusion, solution treated, stretched, T76 overaged). The chemistry is identical, so every difference below comes from the condition. 7449 T76511 is the stronger of the two: yield strength 620 MPa (89.9 ksi) against 110 MPa (16 ksi) for 7449-O, about 5.6 times as much; tensile strength follows at 650 MPa (94.3 ksi) vs 235 MPa (34.1 ksi). In exchange, 7449-O is the more ductile: elongation 16% versus 9% for 7449 T76511, and 7449 T76511 is harder (190 HB vs 65 HB). 7449-O runs hotter in service (200°C vs 120°C continuous) and 7449-O conducts heat better (180 W/m·K vs 145 W/m·K). On the shop floor, 7449 T76511 machines more easily (very good vs fair).
7449-OChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.
7449 T76511Choose it when strength drives the design, or when the part is machined in volume.
7449-O vs 7449 T76511: propertiesHow to read these bars
- One bar per material. A full bar is the highest value among all aluminum grades in the FabDigit library; each bar is drawn as a share of that.
- The better value (by the usual engineering direction) is in bold. Rows with no direction — density, thermal conductivity — have no bold.
- Values are typical room-temperature figures for the condition named on each card.
- Confirm against the certified mill or resin datasheet before design release.
How to read these bars
- One bar per material. A full bar is the highest value among all aluminum grades in the FabDigit library; each bar is drawn as a share of that.
- The better value (by the usual engineering direction) is in bold. Rows with no direction — density, thermal conductivity — have no bold.
- Values are typical room-temperature figures for the condition named on each card.
- Confirm against the certified mill or resin datasheet before design release.
Mechanical
Strength, stiffness, ductility and hardness at room temperature.
Tensile Strength (Ultimate)
Yield Strength (0.2% offset)
Elongation at Break
Compressive Strength
Shear Strength
Fatigue Strength (Endurance Limit)
Fracture Toughness (K_IC)
Hardness, Brinell
Hardness, Vickers
Same in both: Elastic (Young's) Modulus 70 GPa10.2 Msi · Shear Modulus 26.5 GPa3.8 Msi · Bulk Modulus 71 GPa10.3 Msi · Poisson's Ratio 0.33
Physical
Density and transition temperatures.
Same in both: Density 2.82 g/cm³0.1 lb/in³ · Melting Point (Solidus) 475°C887 °F · Liquidus Temperature 635°C1,175 °F
Thermal
How each material carries heat and how hot it can run.
Thermal Conductivity
Max Service Temperature (continuous)
Same in both: Specific Heat Capacity 860 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.4 µm/m·K13 µin/in·°F · Latent Heat of Fusion 390 J/g168 BTU/lb · Min Service Temperature -196°C-321 °F
Electrical
Conductivity and insulation.
Electrical Conductivity
Electrical Resistivity
Chemical & Environmental
Corrosion and environmental resistance (0–100 scores).
Corrosion Resistance
Same in both: Galvanic Potential (seawater, vs SCE) -0.83 V
Manufacturability
FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.
Machinability
Machinability Rating (AISI 1212 = 100 %)
Weldability
Formability (cold)
Same in both: Brazeability / Solderability 10 / 100 · Polishability 60 / 100
Sustainability
Primary-production footprint per kilogram.
Same in both: Embodied Energy (primary production) 205 MJ/kg88,134 BTU/lb · Embodied Carbon (primary production) 12.5 kg CO₂/kg · Embodied Water 1,150 L/kg138 gal/lb · Typical Recycled Content 12%
Strength versus weight
Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.
7449-O vs 7449 T76511 — frequently asked
Is 7449 T76511 stronger than 7449-O?
Yes. 7449 T76511 has a typical yield strength of 620 MPa (89.9 ksi) against 110 MPa (16 ksi) for 7449-O — about 5.6 times as much. Tensile strength is 650 MPa (94.3 ksi) vs 235 MPa (34.1 ksi).
Which condition does FabDigit quote by default, O or T76511?
T7951 is the default 7449 condition in the FabDigit quote flow (neither O nor T76511). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.
Which is easier to machine, 7449-O or 7449 T76511?
7449 T76511. Its machinability rates very good (79/100) against fair (45/100) for 7449-O.