FabDigitFabDigit

Aluminum 7072-H12 vs 7072-H19

Aluminum · 7072 temper comparison

7072-H12 and 7072-H19 are two conditions of the same aluminum grade, 7072: H12 (strain hardened, quarter hard) versus H19 (strain hardened, extra hard). The chemistry is identical, so every difference below comes from the condition. 7072-H19 is the stronger of the two: yield strength 150 MPa (21.8 ksi) against 75 MPa (10.9 ksi) for 7072-H12, about 100% more; tensile strength follows at 165 MPa (23.9 ksi) vs 95 MPa (13.8 ksi). In exchange, 7072-H12 is the more ductile: elongation 12% versus 3% for 7072-H19, and 7072-H19 is harder (46 HB vs 27 HB). 7072-H12 runs hotter in service (120°C vs 100°C continuous). On the shop floor, 7072-H19 machines more easily (fair vs poor).

7072-H12Choose it when the part is bent, formed or impact-loaded, or when the part sees heat.

7072-H19Choose it when strength drives the design, or when the part is machined in volume.

7072-H12 vs 7072-H19: properties

7072-H127072-H19

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

95 MPa13.8 ksi
165 MPa23.9 ksi

Yield Strength (0.2% offset)

75 MPa10.9 ksi
150 MPa21.8 ksi

Elongation at Break

12%
3%

Shear Strength

60 MPa8.7 ksi
90 MPa13.1 ksi

Fatigue Strength (Endurance Limit)

40 MPa5.8 ksi
58 MPa8.4 ksi

Hardness, Brinell

27 HB
46 HB

Same in both: Elastic (Young's) Modulus 69 GPa10 Msi · Shear Modulus 26 GPa3.8 Msi · Bulk Modulus 69 GPa10 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.72 g/cm³0.1 lb/in³ · Melting Point (Solidus) 640°C1,184 °F · Liquidus Temperature 657°C1,215 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

225 W/m·K130 BTU/hr·ft·°F
222 W/m·K128 BTU/hr·ft·°F

Max Service Temperature (continuous)

120°C248 °F
100°C212 °F

Same in both: Specific Heat Capacity 900 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.6 µm/m·K13.1 µin/in·°F · Latent Heat of Fusion 395 J/g170 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

59 % IACS
58 % IACS

Electrical Resistivity

2.92×10⁻⁸ Ω·m1.15 µΩ·in
2.97×10⁻⁸ Ω·m1.17 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

72 / 100
71 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.96 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

32 / 100
42 / 100

Machinability Rating (AISI 1212 = 100 %)

32%
42%

Weldability

80 / 100
75 / 100

Formability (cold)

85 / 100
35 / 100

Same in both: Brazeability / Solderability 80 / 100 · Polishability 45 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 13 kg CO₂/kg · Embodied Water 1,200 L/kg144 gal/lb · Typical Recycled Content 20%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale7072

7072-H12 vs 7072-H19 — frequently asked

Is 7072-H19 stronger than 7072-H12?

Yes. 7072-H19 has a typical yield strength of 150 MPa (21.8 ksi) against 75 MPa (10.9 ksi) for 7072-H12 — about 100% more. Tensile strength is 165 MPa (23.9 ksi) vs 95 MPa (13.8 ksi).

Which condition does FabDigit quote by default, H12 or H19?

Specify the condition in the material field or the drawing note; FabDigit prices the quote for the state you call out.

Which is easier to machine, 7072-H12 or 7072-H19?

7072-H19. Its machinability rates fair (42/100) against poor (32/100) for 7072-H12; for welding the order is 7072-H12 first (very good, 80/100) then 7072-H19 (very good, 75/100).

Ready to make it?

Upload a CAD file and FabDigit prices the part in 7072-H12 and 7072-H19 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.