FabDigitFabDigit

Aluminum 7049-T7351 vs 7049-T7452

Aluminum · 7049 temper comparison

7049-T7351 and 7049-T7452 are two conditions of the same aluminum grade, 7049: T7351 (T73, stress relieved by stretching) versus T7452 (t74-type overage, stress-relieved by compression). The chemistry is identical, so every difference below comes from the condition. 7049-T7452 is the stronger of the two: yield strength 485 MPa (70.3 ksi) against 455 MPa (66 ksi) for 7049-T7351, about 7% more. 7049-T7452 is harder — 137 HB against 130 HB for 7049-T7351 — which matters for wear surfaces and threads.

7049-T7452Choose it when strength drives the design, or when surface hardness matters.

7049-T7351 vs 7049-T7452: properties

7049-T73517049-T7452

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

525 MPa76.1 ksi
550 MPa79.8 ksi

Yield Strength (0.2% offset)

455 MPa66 ksi
485 MPa70.3 ksi

Elongation at Break

11%
10%

Reduction in Area

22%
21%

Compressive Strength

490 MPa71.1 ksi
500 MPa72.5 ksi

Shear Strength

315 MPa45.7 ksi
330 MPa47.9 ksi

Fatigue Strength (Endurance Limit)

155 MPa22.5 ksi
160 MPa23.2 ksi

Fracture Toughness (K_IC)

34 MPa·√m30.9 ksi·√in
32 MPa·√m29.1 ksi·√in

Hardness, Brinell

130 HB
137 HB

Hardness, Vickers

150 HV
152 HV

Same in both: Elastic (Young's) Modulus 71.7 GPa10.4 Msi · Shear Modulus 26.9 GPa3.9 Msi · Bulk Modulus 71 GPa10.3 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.84 g/cm³0.1 lb/in³ · Melting Point (Solidus) 477°C891 °F · Liquidus Temperature 635°C1,175 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

154 W/m·K89 BTU/hr·ft·°F
150 W/m·K86.7 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 960 J/kg·K0.23 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.4 µm/m·K13 µin/in·°F · Latent Heat of Fusion 390 J/g168 BTU/lb · Max Service Temperature (continuous) 150°C302 °F · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

40 % IACS
39 % IACS

Electrical Resistivity

4.3×10⁻⁸ Ω·m1.69 µΩ·in
4.4×10⁻⁸ Ω·m1.73 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

48 / 100
46 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.84 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

74 / 100
72 / 100

Formability (cold)

22 / 100
20 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 70% · Weldability 15 / 100 · Castability 20 / 100 · Brazeability / Solderability 10 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 215 MJ/kg92,433 BTU/lb · Embodied Carbon (primary production) 13.5 kg CO₂/kg · Embodied Water 1,200 L/kg144 gal/lb · Typical Recycled Content 10%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale7049

7049-T7351 vs 7049-T7452 — frequently asked

Is 7049-T7452 stronger than 7049-T7351?

Yes. 7049-T7452 has a typical yield strength of 485 MPa (70.3 ksi) against 455 MPa (66 ksi) for 7049-T7351 — about 7% more. Tensile strength is 550 MPa (79.8 ksi) vs 525 MPa (76.1 ksi).

Which condition does FabDigit quote by default, T7351 or T7452?

Specify the condition in the material field or the drawing note; FabDigit prices the quote for the state you call out.

When should I choose 7049-T7351 over 7049-T7452?

Pick 7049-T7452 when strength drives the design, or when surface hardness matters.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 7049-T7351 and 7049-T7452 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.