7020-O and 7020-T6 are two conditions of the same aluminum grade, 7020: O (annealed) versus T6 (solution heat treated and artificially aged). The chemistry is identical, so every difference below comes from the condition. 7020-T6 is the stronger of the two: yield strength 340 MPa (49.3 ksi) against 115 MPa (16.7 ksi) for 7020-O, about 196% more; tensile strength follows at 385 MPa (55.8 ksi) vs 225 MPa (32.6 ksi). In exchange, 7020-O is the more ductile: elongation 17% versus 12% for 7020-T6, and 7020-T6 is harder (120 HB vs 60 HB). 7020-O runs hotter in service (150°C vs 120°C continuous) and 7020-O conducts heat better (160 W/m·K vs 125 W/m·K). On the shop floor, 7020-T6 machines more easily (good vs fair).

7020-OChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

7020-T6Choose it when strength drives the design, or when the part is machined in volume.

7020-O vs 7020-T6: properties

7020-O7020-T6

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

225 MPa32.6 ksi
385 MPa55.8 ksi

Yield Strength (0.2% offset)

115 MPa16.7 ksi
340 MPa49.3 ksi

Elongation at Break

17%
12%

Shear Strength

145 MPa21 ksi
215 MPa31.2 ksi

Fatigue Strength (Endurance Limit)

90 MPa13.1 ksi
140 MPa20.3 ksi

Hardness, Brinell

60 HB
120 HB

Hardness, Vickers

63 HV
128 HV

Same in both: Elastic (Young's) Modulus 70 GPa10.2 Msi · Shear Modulus 26.4 GPa3.8 Msi · Bulk Modulus 71 GPa10.3 Msi · Poisson's Ratio 0.33 · Compressive Strength 345 MPa50 ksi · Fracture Toughness (K_IC) 32 MPa·√m29.1 ksi·√in

Physical

Density and transition temperatures.

Same in both: Density 2.78 g/cm³0.1 lb/in³ · Melting Point (Solidus) 605°C1,121 °F · Liquidus Temperature 650°C1,202 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

160 W/m·K92.4 BTU/hr·ft·°F
125 W/m·K72.2 BTU/hr·ft·°F

Max Service Temperature (continuous)

150°C302 °F
120°C248 °F

Same in both: Specific Heat Capacity 875 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.1 µm/m·K12.8 µin/in·°F · Latent Heat of Fusion 390 J/g168 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

40 % IACS
32 % IACS

Electrical Resistivity

4.3×10⁻⁸ Ω·m1.69 µΩ·in
5.4×10⁻⁸ Ω·m2.13 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

62 / 100
55 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.84 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

35 / 100
55 / 100

Formability (cold)

80 / 100
30 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 60% · Weldability 78 / 100 · Castability 25 / 100 · Brazeability / Solderability 20 / 100 · Polishability 55 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12.5 kg CO₂/kg · Embodied Water 1,200 L/kg144 gal/lb · Typical Recycled Content 25%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale7020

7020-O vs 7020-T6 — frequently asked

Is 7020-T6 stronger than 7020-O?

Yes. 7020-T6 has a typical yield strength of 340 MPa (49.3 ksi) against 115 MPa (16.7 ksi) for 7020-O — about 196% more. Tensile strength is 385 MPa (55.8 ksi) vs 225 MPa (32.6 ksi).

Which condition does FabDigit quote by default, O or T6?

Specify the condition in the material field or the drawing note; FabDigit prices the quote for the state you call out.

Which is easier to machine, 7020-O or 7020-T6?

7020-T6. Its machinability rates good (55/100) against fair (35/100) for 7020-O.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 7020-O and 7020-T6 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.