FabDigitFabDigit

Aluminum 6182-T4 vs 6182-T6511

Aluminum · 6182 temper comparison

6182-T4 and 6182-T6511 are two conditions of the same aluminum grade, 6182: T4 (solution heat treated and naturally aged) versus T6511 (T6, stress relieved by stretching, minor straightening). The chemistry is identical, so every difference below comes from the condition. 6182-T6511 is the stronger of the two: yield strength 295 MPa (42.8 ksi) against 130 MPa (18.9 ksi) for 6182-T4, about 127% more; tensile strength follows at 330 MPa (47.9 ksi) vs 235 MPa (34.1 ksi). In exchange, 6182-T4 is the more ductile: elongation 19% versus 10% for 6182-T6511, and 6182-T6511 is harder (98 HB vs 66 HB). 6182-T6511 runs hotter in service (150°C vs 100°C continuous). On the shop floor, 6182-T6511 machines more easily (good vs fair).

6182-T4Choose it when the part is bent, formed or impact-loaded.

6182-T6511Choose it when strength drives the design, or when the part sees heat.

6182-T4 vs 6182-T6511: properties

6182-T46182-T6511

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

235 MPa34.1 ksi
330 MPa47.9 ksi

Yield Strength (0.2% offset)

130 MPa18.9 ksi
295 MPa42.8 ksi

Elongation at Break

19%
10%

Shear Strength

150 MPa21.8 ksi
205 MPa29.7 ksi

Fatigue Strength (Endurance Limit)

85 MPa12.3 ksi
95 MPa13.8 ksi

Fracture Toughness (K_IC)

35 MPa·√m31.9 ksi·√in
29 MPa·√m26.4 ksi·√in

Charpy V-Notch Impact (RT)

26 J19.2 ft·lbf
18 J13.3 ft·lbf

Hardness, Brinell

66 HB
98 HB

Hardness, Rockwell B

32 HRB
60 HRB

Hardness, Vickers

70 HV
105 HV

Same in both: Elastic (Young's) Modulus 69.5 GPa10.1 Msi · Shear Modulus 26 GPa3.8 Msi · Bulk Modulus 69 GPa10 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.7 g/cm³0.1 lb/in³ · Melting Point (Solidus) 585°C1,085 °F · Liquidus Temperature 650°C1,202 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

155 W/m·K89.6 BTU/hr·ft·°F
170 W/m·K98.2 BTU/hr·ft·°F

Max Service Temperature (continuous)

100°C212 °F
150°C302 °F

Same in both: Specific Heat Capacity 900 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.4 µm/m·K13 µin/in·°F · Latent Heat of Fusion 393 J/g169 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

39 % IACS
42 % IACS

Electrical Resistivity

4.4×10⁻⁸ Ω·m1.73 µΩ·in
4.1×10⁻⁸ Ω·m1.61 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

66 / 100
65 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.74 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

42 / 100
62 / 100

Machinability Rating (AISI 1212 = 100 %)

100%
150%

Formability (cold)

70 / 100
44 / 100

Same in both: Weldability 72 / 100 · Castability 35 / 100 · Brazeability / Solderability 45 / 100 · Polishability 70 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12.5 kg CO₂/kg · Embodied Water 1,150 L/kg138 gal/lb · Typical Recycled Content 35%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale6182

6182-T4 vs 6182-T6511 — frequently asked

Is 6182-T6511 stronger than 6182-T4?

Yes. 6182-T6511 has a typical yield strength of 295 MPa (42.8 ksi) against 130 MPa (18.9 ksi) for 6182-T4 — about 127% more. Tensile strength is 330 MPa (47.9 ksi) vs 235 MPa (34.1 ksi).

Which condition does FabDigit quote by default, T4 or T6511?

T6 is the default 6182 condition in the FabDigit quote flow (neither T4 nor T6511). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 6182-T4 or 6182-T6511?

6182-T6511. Its machinability rates good (62/100) against fair (42/100) for 6182-T4.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 6182-T4 and 6182-T6511 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.