FabDigitFabDigit

Aluminum 6101A-T5 vs 6101A-T61

Aluminum · 6101A temper comparison

6101A-T5 and 6101A-T61 are two conditions of the same aluminum grade, 6101A: T5 (cooled from hot working and artificially aged) versus T61 (T6 variant, underaged). The chemistry is identical, so every difference below comes from the condition. 6101A-T5 is the stronger of the two: yield strength 150 MPa (21.8 ksi) against 103 MPa (14.9 ksi) for 6101A-T61, about 46% more; tensile strength follows at 180 MPa (26.1 ksi) vs 152 MPa (22 ksi). In exchange, 6101A-T61 is the more ductile: elongation 15% versus 12% for 6101A-T5, and 6101A-T5 is harder (62 HB vs 48 HB).

6101A-T5Choose it when strength drives the design.

6101A-T61Choose it when the part is bent, formed or impact-loaded.

6101A-T5 vs 6101A-T61: properties

6101A-T56101A-T61

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

180 MPa26.1 ksi
152 MPa22 ksi

Yield Strength (0.2% offset)

150 MPa21.8 ksi
103 MPa14.9 ksi

Elongation at Break

12%
15%

Shear Strength

115 MPa16.7 ksi
100 MPa14.5 ksi

Fatigue Strength (Endurance Limit)

62 MPa9 ksi
55 MPa8 ksi

Hardness, Brinell

62 HB
48 HB

Hardness, Vickers

66 HV
53 HV

Same in both: Elastic (Young's) Modulus 69 GPa10 Msi · Shear Modulus 26 GPa3.8 Msi · Bulk Modulus 70 GPa10.2 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.7 g/cm³0.1 lb/in³ · Melting Point (Solidus) 621°C1,150 °F · Liquidus Temperature 654°C1,209 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

214 W/m·K124 BTU/hr·ft·°F
222 W/m·K128 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 895 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.4 µm/m·K13 µin/in·°F · Latent Heat of Fusion 397 J/g171 BTU/lb · Max Service Temperature (continuous) 150°C302 °F · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

56 % IACS
59 % IACS

Electrical Resistivity

3.08×10⁻⁸ Ω·m1.21 µΩ·in
2.92×10⁻⁸ Ω·m1.15 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

72 / 100
74 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.8 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

38 / 100
33 / 100

Machinability Rating (AISI 1212 = 100 %)

38%
33%

Weldability

85 / 100
88 / 100

Formability (cold)

60 / 100
75 / 100

Same in both: Brazeability / Solderability 60 / 100 · Polishability 65 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12.5 kg CO₂/kg · Embodied Water 1,200 L/kg144 gal/lb · Typical Recycled Content 25%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale6101A

6101A-T5 vs 6101A-T61 — frequently asked

Is 6101A-T5 stronger than 6101A-T61?

Yes. 6101A-T5 has a typical yield strength of 150 MPa (21.8 ksi) against 103 MPa (14.9 ksi) for 6101A-T61 — about 46% more. Tensile strength is 180 MPa (26.1 ksi) vs 152 MPa (22 ksi).

Which condition does FabDigit quote by default, T5 or T61?

T6 is the default 6101A condition in the FabDigit quote flow (neither T5 nor T61). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 6101A-T5 or 6101A-T61?

6101A-T5. Its machinability rates fair (38/100) against poor (33/100) for 6101A-T61.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 6101A-T5 and 6101A-T61 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.