FabDigitFabDigit

Aluminum 6069-T4 vs 6069-T6511

Aluminum · 6069 temper comparison

6069-T4 and 6069-T6511 are two conditions of the same aluminum grade, 6069: T4 (solution heat treated and naturally aged) versus T6511 (T6, stress relieved by stretching, minor straightening). The chemistry is identical, so every difference below comes from the condition. 6069-T6511 is the stronger of the two: yield strength 385 MPa (55.8 ksi) against 180 MPa (26.1 ksi) for 6069-T4, about 114% more; tensile strength follows at 420 MPa (60.9 ksi) vs 295 MPa (42.8 ksi). In exchange, 6069-T4 is the more ductile: elongation 20% versus 12% for 6069-T6511, and 6069-T6511 is harder (122 HB vs 80 HB). On the shop floor, 6069-T6511 machines more easily (good vs fair).

6069-T4Choose it when the part is bent, formed or impact-loaded.

6069-T6511Choose it when strength drives the design, or when the part is machined in volume.

6069-T4 vs 6069-T6511: properties

6069-T46069-T6511

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

295 MPa42.8 ksi
420 MPa60.9 ksi

Yield Strength (0.2% offset)

180 MPa26.1 ksi
385 MPa55.8 ksi

Elongation at Break

20%
12%

Compressive Strength

385 MPa55.8 ksi
390 MPa56.6 ksi

Shear Strength

190 MPa27.6 ksi
252 MPa36.5 ksi

Fatigue Strength (Endurance Limit)

100 MPa14.5 ksi
132 MPa19.1 ksi

Hardness, Brinell

80 HB
122 HB

Hardness, Rockwell B

75 HRB
76 HRB

Hardness, Vickers

130 HV
132 HV

Same in both: Elastic (Young's) Modulus 69.5 GPa10.1 Msi · Shear Modulus 26 GPa3.8 Msi · Bulk Modulus 69 GPa10 Msi · Poisson's Ratio 0.33 · Reduction in Area 30% · Fracture Toughness (K_IC) 28 MPa·√m25.5 ksi·√in · Charpy V-Notch Impact (RT) 12 J8.9 ft·lbf

Physical

Density and transition temperatures.

Same in both: Density 2.71 g/cm³0.1 lb/in³ · Melting Point (Solidus) 580°C1,076 °F · Liquidus Temperature 650°C1,202 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

170 W/m·K98.2 BTU/hr·ft·°F
165 W/m·K95.3 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 896 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.2 µm/m·K12.9 µin/in·°F · Latent Heat of Fusion 395 J/g170 BTU/lb · Max Service Temperature (continuous) 150°C302 °F · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

42 % IACS
40 % IACS

Same in both: Electrical Resistivity 4.31×10⁻⁸ Ω·m1.7 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.76 V · Corrosion Resistance 55 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

45 / 100
60 / 100

Machinability Rating (AISI 1212 = 100 %)

55%
57%

Weldability

62 / 100
60 / 100

Formability (cold)

60 / 100
28 / 100

Same in both: Castability 35 / 100 · Brazeability / Solderability 35 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 205 MJ/kg88,134 BTU/lb · Embodied Carbon (primary production) 12.5 kg CO₂/kg · Embodied Water 1,150 L/kg138 gal/lb · Typical Recycled Content 25%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale6069

6069-T4 vs 6069-T6511 — frequently asked

Is 6069-T6511 stronger than 6069-T4?

Yes. 6069-T6511 has a typical yield strength of 385 MPa (55.8 ksi) against 180 MPa (26.1 ksi) for 6069-T4 — about 114% more. Tensile strength is 420 MPa (60.9 ksi) vs 295 MPa (42.8 ksi).

Which condition does FabDigit quote by default, T4 or T6511?

T6 is the default 6069 condition in the FabDigit quote flow (neither T4 nor T6511). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 6069-T4 or 6069-T6511?

6069-T6511. Its machinability rates good (60/100) against fair (45/100) for 6069-T4.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 6069-T4 and 6069-T6511 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.