FabDigitFabDigit

Aluminum 6063-T4 vs 6063-T5

Aluminum · 6063 temper comparison

6063-T4 and 6063-T5 are two conditions of the same aluminum grade, 6063: T4 (solution heat treated and naturally aged) versus T5 (cooled from hot working and artificially aged). The chemistry is identical, so every difference below comes from the condition. 6063-T5 is the stronger of the two: yield strength 145 MPa (21 ksi) against 90 MPa (13.1 ksi) for 6063-T4, about 61% more; tensile strength follows at 186 MPa (27 ksi) vs 172 MPa (24.9 ksi). In exchange, 6063-T4 is the more ductile: elongation 22% versus 12% for 6063-T5, and 6063-T5 is harder (60 HB vs 50 HB).

6063-T4Choose it when the part is bent, formed or impact-loaded.

6063-T5Choose it when strength drives the design.

6063-T4 vs 6063-T5: properties

6063-T46063-T5

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

172 MPa24.9 ksi
186 MPa27 ksi

Yield Strength (0.2% offset)

90 MPa13.1 ksi
145 MPa21 ksi

Elongation at Break

22%
12%

Shear Strength

110 MPa16 ksi
117 MPa17 ksi

Hardness, Brinell

50 HB
60 HB

Hardness, Vickers

78 HV
64 HV

Same in both: Elastic (Young's) Modulus 68.9 GPa10 Msi · Shear Modulus 25.8 GPa3.7 Msi · Bulk Modulus 69 GPa10 Msi · Poisson's Ratio 0.33 · Fatigue Strength (Endurance Limit) 69 MPa10 ksi · Fracture Toughness (K_IC) 29 MPa·√m26.4 ksi·√in

Physical

Density and transition temperatures.

Same in both: Density 2.7 g/cm³0.1 lb/in³ · Melting Point (Solidus) 615°C1,139 °F · Liquidus Temperature 655°C1,211 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

193 W/m·K112 BTU/hr·ft·°F
209 W/m·K121 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 900 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.4 µm/m·K13 µin/in·°F · Latent Heat of Fusion 393 J/g169 BTU/lb · Max Service Temperature (continuous) 150°C302 °F · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

50 % IACS
55 % IACS

Electrical Resistivity

3.5×10⁻⁸ Ω·m1.38 µΩ·in
3.1×10⁻⁸ Ω·m1.22 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.83 V · Corrosion Resistance 70 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

45 / 100
50 / 100

Formability (cold)

70 / 100
50 / 100

Same in both: Machinability Rating (AISI 1212 = 100 %) 200% · Weldability 90 / 100 · Brazeability / Solderability 75 / 100 · Polishability 75 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12.5 kg CO₂/kg · Embodied Water 1,200 L/kg144 gal/lb · Typical Recycled Content 35%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale6063

6063-T4 vs 6063-T5 — frequently asked

Is 6063-T5 stronger than 6063-T4?

Yes. 6063-T5 has a typical yield strength of 145 MPa (21 ksi) against 90 MPa (13.1 ksi) for 6063-T4 — about 61% more. Tensile strength is 186 MPa (27 ksi) vs 172 MPa (24.9 ksi).

Which condition does FabDigit quote by default, T4 or T5?

Specify the condition in the material field or the drawing note; FabDigit prices the quote for the state you call out.

Which is easier to machine, 6063-T4 or 6063-T5?

6063-T5, by a small margin. Both rate fair for machinability — 50/100 against 45/100 for 6063-T4.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 6063-T4 and 6063-T5 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.