6061-T5 and 6061-T6 are two conditions of the same aluminum grade, 6061: T5 (cooled from hot working and artificially aged) versus T6 (solution heat treated and artificially aged). The chemistry is identical, so every difference below comes from the condition. 6061-T6 is the stronger of the two: yield strength 276 MPa (40 ksi) against 240 MPa (34.8 ksi) for 6061-T5, about 15% more; tensile strength follows at 310 MPa (45 ksi) vs 260 MPa (37.7 ksi). 6061-T6 is harder — 95 HB against 85 HB for 6061-T5 — which matters for wear surfaces and threads.

6061-T6Choose it when strength drives the design, or when surface hardness matters.

6061-T5 vs 6061-T6: properties

6061-T56061-T6

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

260 MPa37.7 ksi
310 MPa45 ksi

Yield Strength (0.2% offset)

240 MPa34.8 ksi
276 MPa40 ksi

Elongation at Break

11%
12%

Reduction in Area

35%
40%

Compressive Strength

240 MPa34.8 ksi
276 MPa40 ksi

Shear Strength

180 MPa26.1 ksi
207 MPa30 ksi

Fatigue Strength (Endurance Limit)

88 MPa12.8 ksi
96 MPa13.9 ksi

Fracture Toughness (K_IC)

31 MPa·√m28.2 ksi·√in
29 MPa·√m26.4 ksi·√in

Charpy V-Notch Impact (RT)

21 J15.5 ft·lbf
22 J16.2 ft·lbf

Hardness, Brinell

85 HB
95 HB

Hardness, Rockwell B

50 HRB
60 HRB

Hardness, Vickers

90 HV
107 HV

Same in both: Elastic (Young's) Modulus 68.9 GPa10 Msi · Shear Modulus 26 GPa3.8 Msi · Bulk Modulus 69 GPa10 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.7 g/cm³0.1 lb/in³ · Melting Point (Solidus) 582°C1,080 °F · Liquidus Temperature 652°C1,206 °F

Thermal

How each material carries heat and how hot it can run.

Same in both: Thermal Conductivity 167 W/m·K96.5 BTU/hr·ft·°F · Specific Heat Capacity 896 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.6 µm/m·K13.1 µin/in·°F · Latent Heat of Fusion 397 J/g171 BTU/lb · Max Service Temperature (continuous) 170°C338 °F · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Resistivity

4.01×10⁻⁸ Ω·m1.58 µΩ·in
3.99×10⁻⁸ Ω·m1.57 µΩ·in

Same in both: Electrical Conductivity 43 % IACS

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.83 V · Corrosion Resistance 55 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

68 / 100
70 / 100

Formability (cold)

40 / 100
35 / 100

Same in both: Weldability 85 / 100 · Brazeability / Solderability 60 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12.5 kg CO₂/kg · Embodied Water 1,200 L/kg144 gal/lb · Typical Recycled Content 35%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale6061

6061-T5 vs 6061-T6 — frequently asked

Is 6061-T6 stronger than 6061-T5?

Yes. 6061-T6 has a typical yield strength of 276 MPa (40 ksi) against 240 MPa (34.8 ksi) for 6061-T5 — about 15% more. Tensile strength is 310 MPa (45 ksi) vs 260 MPa (37.7 ksi).

Which condition does FabDigit quote by default, T5 or T6?

T6 is the default 6061 condition in the FabDigit quote flow. The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

When should I choose 6061-T5 over 6061-T6?

Pick 6061-T6 when strength drives the design, or when surface hardness matters.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 6061-T5 and 6061-T6 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.