FabDigitFabDigit

Aluminum 6053-T4 vs 6053-T62

Aluminum · 6053 temper comparison

6053-T4 and 6053-T62 are two conditions of the same aluminum grade, 6053: T4 (solution heat treated and naturally aged) versus T62 (T6, heat treated by the user). The chemistry is identical, so every difference below comes from the condition. 6053-T62 is the stronger of the two: yield strength 215 MPa (31.2 ksi) against 110 MPa (16 ksi) for 6053-T4, about 95% more; tensile strength follows at 255 MPa (37 ksi) vs 195 MPa (28.3 ksi). In exchange, 6053-T4 is the more ductile: elongation 22% versus 13% for 6053-T62, and 6053-T62 is harder (80 HB vs 55 HB). On the shop floor, 6053-T62 machines more easily (good vs fair).

6053-T4Choose it when the part is bent, formed or impact-loaded.

6053-T62Choose it when strength drives the design, or when the part is machined in volume.

6053-T4 vs 6053-T62: properties

6053-T46053-T62

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

195 MPa28.3 ksi
255 MPa37 ksi

Yield Strength (0.2% offset)

110 MPa16 ksi
215 MPa31.2 ksi

Elongation at Break

22%
13%

Shear Strength

130 MPa18.9 ksi
165 MPa23.9 ksi

Fatigue Strength (Endurance Limit)

82 MPa11.9 ksi
90 MPa13.1 ksi

Hardness, Brinell

55 HB
80 HB

Same in both: Elastic (Young's) Modulus 69 GPa10 Msi · Shear Modulus 26 GPa3.8 Msi · Bulk Modulus 69 GPa10 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.69 g/cm³0.1 lb/in³ · Melting Point (Solidus) 585°C1,085 °F · Liquidus Temperature 650°C1,202 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

160 W/m·K92.4 BTU/hr·ft·°F
172 W/m·K99.4 BTU/hr·ft·°F

Same in both: Specific Heat Capacity 895 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.4 µm/m·K13 µin/in·°F · Latent Heat of Fusion 397 J/g171 BTU/lb · Max Service Temperature (continuous) 150°C302 °F · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

42 % IACS
45 % IACS

Same in both: Electrical Resistivity 3.83×10⁻⁸ Ω·m1.51 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.83 V · Corrosion Resistance 72 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

45 / 100
55 / 100

Formability (cold)

65 / 100
42 / 100

Same in both: Weldability 75 / 100 · Brazeability / Solderability 55 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12.5 kg CO₂/kg · Embodied Water 1,200 L/kg144 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale6053

6053-T4 vs 6053-T62 — frequently asked

Is 6053-T62 stronger than 6053-T4?

Yes. 6053-T62 has a typical yield strength of 215 MPa (31.2 ksi) against 110 MPa (16 ksi) for 6053-T4 — about 95% more. Tensile strength is 255 MPa (37 ksi) vs 195 MPa (28.3 ksi).

Which condition does FabDigit quote by default, T4 or T62?

T6 is the default 6053 condition in the FabDigit quote flow (neither T4 nor T62). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 6053-T4 or 6053-T62?

6053-T62. Its machinability rates good (55/100) against fair (45/100) for 6053-T4.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 6053-T4 and 6053-T62 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.