FabDigitFabDigit

Aluminum 6053-O vs 6053-T61

Aluminum · 6053 temper comparison

6053-O and 6053-T61 are two conditions of the same aluminum grade, 6053: O (annealed) versus T61 (T6 variant, underaged). The chemistry is identical, so every difference below comes from the condition. 6053-T61 is the stronger of the two: yield strength 170 MPa (24.7 ksi) against 55 MPa (7.98 ksi) for 6053-O, about 3.1 times as much; tensile strength follows at 220 MPa (31.9 ksi) vs 110 MPa (16 ksi). In exchange, 6053-O is the more ductile: elongation 35% versus 13% for 6053-T61, and 6053-T61 is harder (65 HB vs 26 HB). 6053-O runs hotter in service (200°C vs 150°C continuous). On the shop floor, 6053-T61 machines more easily (50 vs 35 out of 100).

6053-OChoose it when the part is bent, formed or impact-loaded, or when the part sees heat.

6053-T61Choose it when strength drives the design, or when the part is machined in volume.

6053-O vs 6053-T61: properties

6053-O6053-T61

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

110 MPa16 ksi
220 MPa31.9 ksi

Yield Strength (0.2% offset)

55 MPa8 ksi
170 MPa24.7 ksi

Elongation at Break

35%
13%

Shear Strength

76 MPa11 ksi
145 MPa21 ksi

Fatigue Strength (Endurance Limit)

62 MPa9 ksi
83 MPa12 ksi

Hardness, Brinell

26 HB
65 HB

Same in both: Elastic (Young's) Modulus 69 GPa10 Msi · Shear Modulus 26 GPa3.8 Msi · Bulk Modulus 69 GPa10 Msi · Poisson's Ratio 0.33

Physical

Density and transition temperatures.

Same in both: Density 2.69 g/cm³0.1 lb/in³ · Melting Point (Solidus) 585°C1,085 °F · Liquidus Temperature 650°C1,202 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

180 W/m·K104 BTU/hr·ft·°F
170 W/m·K98.2 BTU/hr·ft·°F

Max Service Temperature (continuous)

200°C392 °F
150°C302 °F

Same in both: Specific Heat Capacity 895 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.4 µm/m·K13 µin/in·°F · Latent Heat of Fusion 397 J/g171 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

47 % IACS
44 % IACS

Same in both: Electrical Resistivity 3.83×10⁻⁸ Ω·m1.51 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Same in both: Galvanic Potential (seawater, vs SCE) -0.83 V · Corrosion Resistance 72 / 100

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

35 / 100
50 / 100

Formability (cold)

90 / 100
55 / 100

Same in both: Weldability 75 / 100 · Brazeability / Solderability 55 / 100 · Polishability 60 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 200 MJ/kg85,985 BTU/lb · Embodied Carbon (primary production) 12.5 kg CO₂/kg · Embodied Water 1,200 L/kg144 gal/lb · Typical Recycled Content 30%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale6053

6053-O vs 6053-T61 — frequently asked

Is 6053-T61 stronger than 6053-O?

Yes. 6053-T61 has a typical yield strength of 170 MPa (24.7 ksi) against 55 MPa (7.98 ksi) for 6053-O — about 3.1 times as much. Tensile strength is 220 MPa (31.9 ksi) vs 110 MPa (16 ksi).

Which condition does FabDigit quote by default, O or T61?

T6 is the default 6053 condition in the FabDigit quote flow (neither O nor T61). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 6053-O or 6053-T61?

6053-T61, by a small margin. Both rate fair for machinability — 50/100 against 35/100 for 6053-O.

Ready to make it?

Upload a CAD file and FabDigit prices the part in 6053-O and 6053-T61 side by side — material, machining time, tolerance and finish in one quote. Certified material data ships with the order on request.

Typical handbook values for the conditions named above, normalised for comparison. Hardness on non-Brinell scales is converted approximately for charting only. Request certified data with your order for design-critical properties.