6012-T4 and 6012-T651 are two conditions of the same aluminum grade, 6012: T4 (solution heat treated and naturally aged) versus T651 (T6, stress relieved by stretching). The chemistry is identical, so every difference below comes from the condition. 6012-T651 is the stronger of the two: yield strength 295 MPa (42.8 ksi) against 150 MPa (21.8 ksi) for 6012-T4, about 97% more; tensile strength follows at 330 MPa (47.9 ksi) vs 255 MPa (37 ksi). In exchange, 6012-T4 is the more ductile: elongation 16% versus 10% for 6012-T651, and 6012-T651 is harder (100 HB vs 70 HB). 6012-T651 runs hotter in service (150°C vs 100°C continuous). On the shop floor, 6012-T651 machines more easily (96 vs 85 out of 100).

6012-T4Choose it when the part is bent, formed or impact-loaded.

6012-T651Choose it when strength drives the design, or when the part sees heat.

6012-T4 vs 6012-T651: properties

6012-T46012-T651

Mechanical

Strength, stiffness, ductility and hardness at room temperature.

Tensile Strength (Ultimate)

255 MPa37 ksi
330 MPa47.9 ksi

Yield Strength (0.2% offset)

150 MPa21.8 ksi
295 MPa42.8 ksi

Elongation at Break

16%
10%

Shear Strength

165 MPa23.9 ksi
210 MPa30.5 ksi

Fatigue Strength (Endurance Limit)

85 MPa12.3 ksi
100 MPa14.5 ksi

Hardness, Brinell

70 HB
100 HB

Hardness, Vickers

75 HV
108 HV

Same in both: Elastic (Young's) Modulus 69 GPa10 Msi · Shear Modulus 26 GPa3.8 Msi · Bulk Modulus 69 GPa10 Msi · Poisson's Ratio 0.33 · Fracture Toughness (K_IC) 26 MPa·√m23.7 ksi·√in · Hardness, Rockwell B 60 HRB

Physical

Density and transition temperatures.

Same in both: Density 2.72 g/cm³0.1 lb/in³ · Melting Point (Solidus) 580°C1,076 °F · Liquidus Temperature 650°C1,202 °F

Thermal

How each material carries heat and how hot it can run.

Thermal Conductivity

155 W/m·K89.6 BTU/hr·ft·°F
165 W/m·K95.3 BTU/hr·ft·°F

Max Service Temperature (continuous)

100°C212 °F
150°C302 °F

Same in both: Specific Heat Capacity 890 J/kg·K0.21 BTU/lb·°F · Thermal Expansion (CTE, 20–100 °C) 23.4 µm/m·K13 µin/in·°F · Latent Heat of Fusion 390 J/g168 BTU/lb · Min Service Temperature -196°C-321 °F

Electrical

Conductivity and insulation.

Electrical Conductivity

37 % IACS
40 % IACS

Electrical Resistivity

4.7×10⁻⁸ Ω·m1.85 µΩ·in
4.3×10⁻⁸ Ω·m1.69 µΩ·in

Chemical & Environmental

Corrosion and environmental resistance (0–100 scores).

Corrosion Resistance

55 / 100
58 / 100

Same in both: Galvanic Potential (seawater, vs SCE) -0.78 V

Manufacturability

FabDigit workshop ratings (0–100 scores) — how each material behaves on the machine.

Machinability

85 / 100
96 / 100

Machinability Rating (AISI 1212 = 100 %)

230%
300%

Formability (cold)

50 / 100
20 / 100

Same in both: Weldability 20 / 100 · Castability 35 / 100 · Brazeability / Solderability 25 / 100 · Polishability 45 / 100

Sustainability

Primary-production footprint per kilogram.

Same in both: Embodied Energy (primary production) 205 MJ/kg88,134 BTU/lb · Embodied Carbon (primary production) 12.5 kg CO₂/kg · Embodied Water 1,200 L/kg144 gal/lb · Typical Recycled Content 20%

Strength versus weight

Yield strength against density for every aluminum grade in the FabDigit library; the compared grades are highlighted. Up and left is stronger for its weight.

20501002005002.22.42.62.83Density (g/cm³)Yield strength (MPa) — log scale6012

6012-T4 vs 6012-T651 — frequently asked

Is 6012-T651 stronger than 6012-T4?

Yes. 6012-T651 has a typical yield strength of 295 MPa (42.8 ksi) against 150 MPa (21.8 ksi) for 6012-T4 — about 97% more. Tensile strength is 330 MPa (47.9 ksi) vs 255 MPa (37 ksi).

Which condition does FabDigit quote by default, T4 or T651?

T6 is the default 6012 condition in the FabDigit quote flow (neither T4 nor T651). The other condition is available on request or by drawing note — specify it in the material field or the part notes and the quote is priced for it.

Which is easier to machine, 6012-T4 or 6012-T651?

6012-T651, by a small margin. Both rate excellent for machinability — 96/100 against 85/100 for 6012-T4.